EN - 13
MT/AUT/AUT RAB
6 Putting into operation
6.3 Mounting the machine side hose assembly
1
Combine central plug
and central socket
at the wire feed unit
and secure them with the connecting nut
6.4 Connecting the cooling system
1
Hose assembly
2
Coolant return hose
3
Coolant supply hose
4
Re-circulating cooling unit
(only with liquid-cooled torches)
5
Wire basket spool
6
Shielding gas cylinder
7
Power supply
8
Wire feed unit
9
Central socket
10
Central plug
11
Connection nut
Fig. 5
Mounting the hose assembly on the machine side
1
2
3
4
5
6
7
9
11
8
10
NOTE
• Check once again whether the wire guide has been fastened correctly.
WARNING
Risk of burns
Welding torches will become overheated if the coolant level is too low.
• Wear protective gloves.
• Check the coolant level at regular intervals.
NOTE
• Applies only to liquid-cooled welding torches.
• Make sure that the coolant supply and return have been installed
properly. Coolant supply = blue, Coolant return = red