EN - 15
ABITIG
®
WH
8 Putting out of operation
7.1 Welding process
1
Open the shielding gas cylinder.
2
Switch on the power supply.
8 Putting out of operation
1
Wait until the shielding gas flow has subsided.
2
Close the shut-off valve for the gas supply.
3
Switch off the power supply.
9 Maintenance and cleaning
Scheduled maintenance and cleaning is a prerequisite for a long life and a
trouble-free operation.
DANGER
Risk of burns
During welding sparks, glowing work-pieces or hot slag can produce
flames.
• Check work area for fire.
• Make suitable fire extinguishing materials available at the workplace.
• Allow work-pieces to cool down after welding.
• Prior to performing welding work, fasten the ground clamp properly to
the work-piece or the welding table.
WARNING
Arc eye
The arc produced by welding may damage the eyes.
• Wear protective clothing and eye protection.
NOTE
• The welding torch may only be operated by qualified personnel.
• As the TIG welding torch is integrated into a welding system, the
operating instructions of the welding components, such as welding torch
and power supply, must be observed during operation.
• For TIG welding, ensure that all the parameters are set at the power
supply for your welding task.