BAL.0107 • 2019-06-19
EN - 13
ABITIG
®
MT
7 Operation
Ventilate the entire cooling system as follows when used for the first time and after every hose
assembly change:
1
Disconnect the coolant return hose
from the re-circulating cooling unit
and hold it
over a collecting device.
2
Close the opening at the coolant return hose
and open it again by repeatedly and
abruptly releasing it, until the coolant is flowing continuously and without air bubbles into the
collecting device.
3
Switch off the re-circulating cooling unit
and reconnect the coolant return hose
7 Operation
1
Coolant return hose
2
Re-circulating cooling unit
Fig. 3
Connecting the coolant
1
2
DANGER
Shortness of breath and poisoning caused by inhaling phosgene gas
When welding workpieces that have been degreased with chlorinated solvents, phosgene
gas is formed.
• Do not inhale smoke and vapours.
• Ensure a sufficient supply of fresh air.
• Rinse the workpieces with clean water prior to welding.
• Do not place degreasing baths containing chlorine in the vicinity of the welding area.
DANGER
Risk of burns
During welding activities, sparks, glowing workpieces or hot slag can produce flames.
• Check the work area for flashpoints.
• Provide appropriate fire extinguishing equipment in the workplace.
• Allow workpieces to cool down after welding.
• Prior to performing welding work, properly fasten the ground clamp to the workpiece or
welding table.
Содержание ABITIG MT 200W
Страница 91: ...BAL 0107 2019 06 19 ZH 19 ABITIG MT 记录 记录 ...