BAL.0085 • 2017-03-02
EN - 5
ABIMIG
®
W
3 Product description
3.1 Technical data
With pulse arcs, the load data is reduced by up to 30%.
Transport and storage
−25 °C to +55 °C
Relative humidity
Up to 90% at 20 °C
Tab. 1
Ambient conditions during operation
Type of voltage
DC
DC polarity of the electrodes
Usually positive
Shielding gas (DIN EN ISO 14175)
CO
2
and mixed gas M21
Wire types
Commercially available round wires
Voltage rating
Peak value of 113 V
Protection type of the device connections (EN 60529)
IP3X
Control devices in handle
For 42 V and 0.1 to 1 A
Tab. 2
General torch data (EN 60974-7)
Type
Type of cooling
Load
Duty cycle
Wire
Gas flow rate
DC
M21
CO
2
(A)
(A)
(%)
(mm)
(l/min)
452W
Liquid
500
550
100
0.8–1.6
10–20
452DW
Liquid
450
500
100
0.8–1.6
10–20
645W
Liquid
600
650
100
0.8–1.6
10–20
Tab. 3
Product-specific torch data (EN 60974-7)
Supply temperature
max. 40 °C
Flow
min. 0.9 l/min
Flow pressure
min. 2.5 bar/max. 3.5 bar
Cooling
Dual circuit
Tab. 4
Cooling data
Standard length L
3.00 m, 4.00 m, 5.00 m
Coolant connection
Plug-in nipple, nom. diam. 5
Cooling unit power
min. 800 W
Control lead
2-wire
Tab. 5
Cable assembly