EN - 9
ABIMIG
®
WT
6 Putting out of operation
Using a standard welding torch, the two-cycle mode of the trigger can be
activated. Further operating modes and handle modules depend on the
corresponding welding power supply and must be ordered separately.
5.1 2-cycle function of the trigger
1
Press the trigger on the handle and keep it pressed = welding is started.
2
Release the trigger = welding is stopped.
6 Putting out of operation
1
Wait until the shielding gas flow has subsided and then switch off the power
supply.
2
Close the valve of the shielding gas cylinder.
7 Maintenance and cleaning
7.1 Cable assembly
1
Unscrew the cable assembly on the machine side and bring it into a
stretched position.
2
Unscrew nut and pull out liner or PA liner and replace it, if necessary.
3
Remove wear parts from the torch neck.
NOTE
• Liquid-cooled cable assemblies start leaking when overheated. This is
why the cooling unit should continue running for approx. 5 min. after
welding.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, installation, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply and cut off the gas supply.
• Close off the compressed-air supply and pull the main plug.