EN
-
22
6 Putting into operation
ABICAR 1200 PRO 42V
Setting the welding parameters
The following welding parameters can be set via the navigation.
Tab. 5
Welding parameters overview
Parameters
Value
Description
Carriage speed
0.0–130.0 cm/min
Welding tractor speed
Weld length
1.0–250.0 cm
Weld seam length
Skipping
0.0–100.0 cm
Distance between the weld seams.
Setting “0” will reset the crater fill time and
the crater back-filling. The device welds in
continuous welding mode.
Crater fill
0.0–3.0 s
Crater fill time.
Inactive at distance “0.0”. Indicated by “!”.
Backweld
0.0–2.0 cm
Length of the crater fill.
At maximum, the set weld length. Inactive at
distance “zero”. Indicated by “!”.
Total length
350–1000 cm, unlimited
Total of all weld seam lengths and the
distance between the weld seams.
Infinite = The programme will be executed
until the device is manually switched off.
Current lowering
Yes
NO
YES = The arc current is reduced during
crater fill.
The crater fill time must be greater than or
equal to the arc quenching time set on the
power source.
NO = The arc current is not reduced during
crater fill.
Unit
cm
in
Unit used
Save setup
1–40
Save the current configuration under
the indicated programme number.
Load setup
1–40
Load the saved configuration under
the indicated programme number.
Language
ENGLISH
POLISH
SPANISH
FRENCH
PORTUGUESE
TURKISH
RUSSIAN
GERMAN
ITALIAN
Language for menus
Содержание ABICAR 1200 PRO