background image

CN3-BT control unit

<         R A D I O         >

E N T E R ( O K )

<         L O G I C         >

E N T E R ( O K )

<       P O W E R           >

E N T E R ( O K )

<   P A U S E   T I M E     >

E N T E R ( O K )

< P R O G R A M       >

E N T E R ( O K )

< S E T T I N G S      >

E N T E R ( O K )

< T I M E R         >

E N T E R ( O K )

Q 1     2 2 3           Q 2     6 1 8
I N ^ ^ ^ ^ F ^ ^ S ^ ^ ^ O K !

M O D I F Y   L A N G U A G E

      [ O K ]

OK

>

>

CANC

>+

-<

Press the> + key to move to the next menu

Press OK and then press the key of the remote control you want to program

Press OK and select the logic you want

Press OK and select the time for which the gate must be open in 

AUTOMATIC or CONDOMINIUM logic

Press OK and select the gate strength.

Press OK to enter the run programming procedure (the kits are supplied 

already programmed)

Press OK to change the timer  

Press OK to change the language.

Press OK and enter the password (request it by phone or by mail) to enter

the advanced menu  

Q 1     2 2 3   Q 2     6 1 8
I N ^ ^ ^ ^ F ^ ^ S ^ ^ ^ O K !

ERROR 

OK  : no error

STP : Stop

FT1  : Photocell 1

FT2  : Photocell 2

OC1 : Obstacle current motor 1

OC2 : Obstacle current motor 2

OE1 : Obstacle encoder motor 1

OE2 : Obstacle encoder motor 2

DR1 : Overcurrent motor 1

DR2 : Overcurrent motor 2

ZC1 : No currento motor 1

ZC2 : No currento motor 2

VDW : Voltage too low.

2.1 MENU “STATUS” :

Q1 : Motor 1 position

Q2 : Motor 2 position

Limitswitch C1/Encoder1

Limitswitch A1/Encoder2

Limitswitch C2

Limitswitch A2

Photocell1

Photocell2

Stop

Start1

Start2

^

_

X

Contact is closed

Contact is opened

Contact is deactivated

( see paragraph 9. )

5

Содержание POLY

Страница 1: ...POLY CONTROL UNIT ABEXO is a registered trademark property ABTECNO srl Via Cicogna 95 40068 San Lazzaro di Savena BO info abtecno com www abexo tech AUTOMATION ACCESSORIES AUTOMATIC CHAIN BARRIER ...

Страница 2: ... E F F L A M P E G G V E F F L A M P E G G Wiring schematic BLINKER MASTER LED MASTER 5 4 3 1 2 5 4 3 1 2 1 8 1 D4 R18 P2 P3 P4 P1 IC17 IC5 SLAVE MASTER M2 M1 LED Photocell opening manouvre Photocell closing manouvre NC COM 12 24V dc 12 24V RX NC COM 24V dc 24V RX 2 Password 7732 ...

Страница 3: ...ells available on request PHOTOCELLS Cable types and minimum thickness CONNECTION MOUNTING VOLTAGE 230 V AC FLASHING LIGHT OPTIONAL PHOTOCELL OPTIONAL THICKNESS Unbolt the 8 screws 7 and remove the front cover 4 the rear cover 5 and the plastic cover 6 from the column Insert the column on the base plate be careful that the screws get in the right position with the holes Secure the column to the ba...

Страница 4: ...lumn 3 Align the 4 holes B on the base with the 4 holes B on the column Fix the base to the column with the 4 M10 x 20 screws and the given nuts Tighten the screws firmly The upper module 1 has 2 M10 threaded holes A at its bottom Lean the module on the base Be sure to align the holes and then fix it with the 2 given M10X20 screws POLY RING Assemble the ring as you see in the picture and fix it to...

Страница 5: ...rogramming procedure the kits are supplied already programmed Press OK to change the timer Press OK to change the language Press OK and enter the password request it by phone or by mail to enter the advanced menu Q 1 2 2 3 Q 2 6 1 8 I N F S O K ERROR OK no error STP Stop FT1 Photocell 1 FT2 Photocell 2 OC1 Obstacle current motor 1 OC2 Obstacle current motor 2 OE1 Obstacle encoder motor 1 OE2 Obsta...

Страница 6: ...ONDOMINIUM WITH ANTICIPABLE CLOSING when the barrier is closed a START opens during the opening phase the STARTs are ignored During the pause a START and the darkening of the photocells recharge the pause time the passage in front of the photocell FT1 anticipates the closing at the end of the break the barrier closes automatically During the closing phase one START stops the barrier and another ST...

Страница 7: ...ses beyond a certain threshold value for a time T greater than the time of hysteresis By raising and lowering the threshold value differentiated for slow and fast for motor 1 and motor 2 it is possible to make the automation more or less sensitive to obstacles By raising the hysteresis time it is possible to set the control unit so that it ignores small obstacles by lowering the hysteresis value o...

Страница 8: ...nd check that during this maneuver the chain does not exceed the height of 50 cm from its position of total opening if the chain exceeds this height it is necessary to reduce the motor force 8 verification of the disconnection system of the power supply acting on the disconnection device power supply and disconnecting any buffer batteries check that all the LEDs on the control unit are turned off ...

Страница 9: ...on network Install a bipolar switch disconnector with contact opening equal to or higher than 3mm on the power supply network Verifies that upstream of the electrical system there is a good differential switch an overload protection and a grounding system During installation maintenance and repair work disconnect the power supply before touching the electrical parts The handling of the electrical ...

Отзывы: