Optional accessories mounting

CABLE TYPES AND MINIMUM THICKNESS

4

Place the front cover [4] on both the columns and secure it with the 2 screws [7] near the ground. Attach the chain to the eyebolts that 

protrude from the front covers and tighten it so that the chain at the centre of the passage is at a height X with respect to ground. Before 

moving on placing the rear cover, make the electrical connections, as written in the following paragraph.

Refer to the attached CONT-R15 control unit manual.

POLY-PLUS 

 

Upper module with neutral plate for housing of accessories and control panel

POLY-RING 

 

Safety ring for metallic chain

POLY PLUS

1. Upper module

2. Base

3. Column

Put the base [2] Poly Plus inside the column [3]. Align the 

4 holes [B] on the base with the 4 holes [B] on the 

column.

Fix the base to the column with the 4 M10 x 20 screws 

and the given nuts. Tighten the screws firmly!

The upper module [1] has 2 M10 threaded holes [A] at its 

bottom. Lean the module on the base. Be sure to align 

the holes and then fix it with the 2 given M10X20 screws. 

POLY RING

Assemble the ring as you see 

in the picture and fix it to the 

eyelet and to the last link of 

the chain.

the six-monthly periodic maintenance plan provides for:

- remove 230V power supply or batteries if present
- clean and grease the monorail guide and inner chain sprockets
- grease the tow chain
- check that the screws holding the column are well tightened
- check the electrical connections
- restore power supply
- check obstacle detection operation (encoder system)
- check the correct functioning of all the command and safety functions
- replace any worn parts

MAINTENANCE

Содержание POLY

Страница 1: ...POLY CONTROL UNIT ABEXO is a registered trademark property ABTECNO srl Via Cicogna 95 40068 San Lazzaro di Savena BO info abtecno com www abexo tech AUTOMATION ACCESSORIES AUTOMATIC CHAIN BARRIER ...

Страница 2: ... E F F L A M P E G G V E F F L A M P E G G Wiring schematic BLINKER MASTER LED MASTER 5 4 3 1 2 5 4 3 1 2 1 8 1 D4 R18 P2 P3 P4 P1 IC17 IC5 SLAVE MASTER M2 M1 LED Photocell opening manouvre Photocell closing manouvre NC COM 12 24V dc 12 24V RX NC COM 24V dc 24V RX 2 Password 7732 ...

Страница 3: ...ells available on request PHOTOCELLS Cable types and minimum thickness CONNECTION MOUNTING VOLTAGE 230 V AC FLASHING LIGHT OPTIONAL PHOTOCELL OPTIONAL THICKNESS Unbolt the 8 screws 7 and remove the front cover 4 the rear cover 5 and the plastic cover 6 from the column Insert the column on the base plate be careful that the screws get in the right position with the holes Secure the column to the ba...

Страница 4: ...lumn 3 Align the 4 holes B on the base with the 4 holes B on the column Fix the base to the column with the 4 M10 x 20 screws and the given nuts Tighten the screws firmly The upper module 1 has 2 M10 threaded holes A at its bottom Lean the module on the base Be sure to align the holes and then fix it with the 2 given M10X20 screws POLY RING Assemble the ring as you see in the picture and fix it to...

Страница 5: ...rogramming procedure the kits are supplied already programmed Press OK to change the timer Press OK to change the language Press OK and enter the password request it by phone or by mail to enter the advanced menu Q 1 2 2 3 Q 2 6 1 8 I N F S O K ERROR OK no error STP Stop FT1 Photocell 1 FT2 Photocell 2 OC1 Obstacle current motor 1 OC2 Obstacle current motor 2 OE1 Obstacle encoder motor 1 OE2 Obsta...

Страница 6: ...ONDOMINIUM WITH ANTICIPABLE CLOSING when the barrier is closed a START opens during the opening phase the STARTs are ignored During the pause a START and the darkening of the photocells recharge the pause time the passage in front of the photocell FT1 anticipates the closing at the end of the break the barrier closes automatically During the closing phase one START stops the barrier and another ST...

Страница 7: ...ses beyond a certain threshold value for a time T greater than the time of hysteresis By raising and lowering the threshold value differentiated for slow and fast for motor 1 and motor 2 it is possible to make the automation more or less sensitive to obstacles By raising the hysteresis time it is possible to set the control unit so that it ignores small obstacles by lowering the hysteresis value o...

Страница 8: ...nd check that during this maneuver the chain does not exceed the height of 50 cm from its position of total opening if the chain exceeds this height it is necessary to reduce the motor force 8 verification of the disconnection system of the power supply acting on the disconnection device power supply and disconnecting any buffer batteries check that all the LEDs on the control unit are turned off ...

Страница 9: ...on network Install a bipolar switch disconnector with contact opening equal to or higher than 3mm on the power supply network Verifies that upstream of the electrical system there is a good differential switch an overload protection and a grounding system During installation maintenance and repair work disconnect the power supply before touching the electrical parts The handling of the electrical ...

Отзывы: