background image

15

16

Spare Parts

Fan Components

 External Components

Cables

Duct + Ventilation Accessories

N-100

N-101

N-102

N-1209

N-1206

N-1208

N-1207

Main Control Board

Display Board

RH/Temp. Sensor

Fan Motor

Complete Fan Assembly

Fan Capacitor

N-1210

N-1211

N-1205

N-1200

N-1201

N-1202

N-1203

N-125

Prefilter

MERV 8

HEPA

Carbon Filter

Foot adjustable

Display/Control

Inernal Components

N-120

N-121

N-122

Temp/RH Sensor Cable

Display Ribbon Cable

Ca

Т: 5 Port Internal Cable

N-1204

Supply Duict Collar 

Assembly

Compressor

Compressor Capacitor

Coil Assembly

Condensate Pump

Assembly

W-100

W-101

W-102

Remote Control Assembly 

(includes W-101 and W-102)

Remote Control

Remote Control Cable

Remote Control

Specifications

Power

115V/60HZ

Amperages(max.)

24Amperes

Amperages(at 80

℉/

60

%

RH)

Circuit 1:10.7
Circuit 1:10.8

Process air

395 CFM

65 CFM

Reactivation air

Water removal capacity 
(at 80°F/60%RH)

118 pints per day | 55.8 L per/day

Weight

Dimensions (H × W × D)

33.13 × 21.14 × 20.25 in.
(With handle upright = 42. 250 in.) 
84.15 × 53.7 × 51.4 cm
(With handle upright = 107.3 cm.)

95 lbs. | 43.1 kg

Air filter

Safety

F590 (24 pk)

ETL listed to CSA dehumidifier 
standards

  

I

f the problem you are experiencing is not listed here, contact your local distributor or call our 

Service Department toll-free line at +44 (20) 81243974 for assistance. 

 Parts Included

Reactivation Out duct ring adapter

Reactivation Out heat-resistant ducting, 20 feet × 6 inches

6-inch duct clamp

Air inlet duct ring adapter (optional, installation required)

Process air outlet lay-flat duct adaptor kit (optional, requires installation)

2 power cords, 25 ft. each

Содержание Water Damage AbesTec 4000i

Страница 1: ... we keep upgrading our product we reserve the right to modify the product without natice in advance Abestorm Solutions INC Water Damage Series Add Berlin Tel 44 20 81243974 Email www abestorm com AbesTec 4000i Dehumidifier ...

Страница 2: ...er supply always grasp the plug and not the cord WARNING Risk of Electric shock hot surface rotating fan hazards Power off the unit and unplug from supply before opening the front cover for servicing or cleaning The unit must be connected to a grounded power supply The three prong plug should only be inserted into a matching outlet that is electrically grounded The cord should never be used with a...

Страница 3: ...nstead have a qualified electrician install the correct outlets This equipment should only be used on circuits that have a nominal rating of not above 120V The unit Should Be Handled Carefully Position the unit on a surface that is level and stable when running Do not throw drop or place the unit where it could tumble Rough handling of the unit could lead to damages that void the warranty It could...

Страница 4: ...ction is correct The green light will not illuminate if both the power cords are inserted into the same circuit or when using a single cord For maximum efficiency use both circuits while ensuring that the green light illuminates However the dehumidifier may run on one power cord if the second circuit is not available Plug into Circuit 1 When using a single power cable the dehumidifier operates at ...

Страница 5: ...activation Outlet to an outside location The Reactivation ducting MUST be connected to a reactivation outlet Ducting should not be longer than six meters 20 feet Set the ducting with the least number of bends that can be attained Tips The ducting should slope downwards away from the equipment Always duct the Reactivation Outlet preferably to an outdoor location Notice Sometimes water may collect i...

Страница 6: ...icle Maintenance For more detailed instructions visit www unipdry com WARNING RISK OF ELECTRIC SHOCK Disconnect the unit from the power supply before servicing or cleaning 9 10 WARNING Dust and contaminants exposes you to hazards The use of hand gloves and respirator mask is highly recommended If you realize that the product has been exposed to a possibly harmful contaminant clean thoroughly by di...

Страница 7: ...ter or any kind of cleaning solution Take caution not to damage the electronic sensors and lead wires Reattach the side panel Reattach the sensor cable inside the panel Thread the cable upwards over the zip tie and plug it in Install the screws and fasten sing fingers only starting from the top working downwards Once the screws are correctly started use a hand screw to tighten them lightly do not ...

Страница 8: ...WER FAILURE is not an error message When this message is displayed it indicates that the power supply was interrupted and then reestablished Use the MENU SELECTION key to clear the message Troubleshooting Display is Blank No Airflow Error Code E1 Error Code E4 Error Code LO Error Code HI Tripped GFCI Outlet or Breaker Cause Solution Poor Connection Power Outage Filter is dirty Air Inlet or Outlet ...

Страница 9: ...ntrol Specifications Power 115V 60HZ Amperages max 24Amperes Amperages at 80 60 RH Circuit 1 10 7 Circuit 1 10 8 Process air 395 CFM 65 CFM Reactivation air Water removal capacity at 80 F 60 RH 118 pints per day 55 8 L per day Weight Dimensions H W D 33 13 21 14 20 25 in With handle upright 42 250 in 84 15 53 7 51 4 cm With handle upright 107 3 cm 95 lbs 43 1 kg Air filter Safety F590 24 pk ETL li...

Страница 10: ...rtation charges 1 To gain the full advantage of the warranty the customer is expected to care for the unit including cleaning and routine maintenance 3 All the costs related to transporting the unit to a certified technician will be borne by the owner including ancillary charges such as wrapping labeling picking up the customer and palletizing 2 Reinstallation and removal of the unit will be done ...

Отзывы: