Notice! RH/Temperature
The sensor cable is attached onto the interior of panel. Before
Setting aside the panel, unclip and slide it out from the cable tie

Advanced Pump Cleaning

Complete as needed

1. Press the drain button to drain the water from the reservoir (a wet-dry

vacuum or towels can be used to remove any remaining water).

2. Unplug the dehumidifier and remove the cover so you have access

to the pump.

3. Remove the pump head from the reservoir by unscrewing the screw.

Wipe reservoir clean with a paper towel.

4. Reassemble pump.

5. Mix a 16 ounce solution of bleach (1 oz 15 oz water) OR

vinegar (4 oz white v 12 oz water).

6. Pour the cleaning solution into the drain tray at the base of the coils.

If any cleaning solution gets on the coils, flush with water.

7. Allow solution to soak for 15 minutes.

8. Reconnect the dehumidifier to power.

9. Fill the reservoir with water (16-32 ounces) and flush/cycle the pump

at least 2x.

Unit Diagram

Handle

Side Panel

Filter Cover

Control Panel

Pre-Filter

Discharge Grille

Power Cord

Auxiliary Terminals

Drain Hose 
Connection

11

12

Before setting aside the panel, detach the sensor cable. When 
Replacing the panel, remember to reinstall the cable. 

Air in/ react out panel. Only remove this panel    
 for routine cleaning and inspection

Storage compart-ment.

Blower

Belt tensioner
(see detailbe-
low)

Desiccant
rotor

Reactair
outlet

Belt tensioner.Lift arm upward
to release belt.

Inspect the blower and clean as necessary

Ensure that the impeller rotates without restrictions. Wipe clean or vacuum all surfaces.

Inspect the desiccant rotor and clean as necessary

Use pressurized air or dry-vacuum to get rid of dust collected on the rotor.

Inspect the rotor belt. 

Check for cracks and excessive wear. For replacement 

options, contact your local distributor or retailer.

Vacuum the interior

 to get rid of debris and dust. Wipe the interior surface using a 

clean and dry cloth. Do not attempt to use water or any kind of cleaning solution. 
Take caution not to damage the electronic sensors and lead wires.

Reattach the side panel:

 Reattach the sensor cable inside the panel. Thread the cable 

upwards over the zip tie and plug it in. Install the screws and fasten sing fingers only, 
starting from the top working downwards. Once the screws are correctly started, use a 
hand screw to tighten them lightly, do not overtighten the screws. Also, do not tighten the 
screws using a power screw since they tend to impact more pressure.

PUMP PURGE BUTTON

When the Pump Purge Button is used, the control panel displays 
the following messages.

C O N T R O L P A N E L
M E S S A G E

E X P L A N A T I O N

PLEASE WAIT
CALCULATING

PERFORMANCE
XXX PINTS/24H

The dehumidifier is calculating water removal..

The unit displays the calculated water removal 
in Pints per day.

SYSTEM MESSAGES

The Control Panel will display the following messages based on system performance 
and environmental conditions. User action, if any is required, is indicated in 
the third column. 

C O N T R O L P A N E L
M E S S A G E

E X P L A N A T I O N

U S E R A C T I O N

INITIALIZING

Unit is powering up.  

FIRMWARE 
VERSION XXX

Indicates the control board 
firmware version number

None

None

Содержание Water Damage AbesTec 4000i

Страница 1: ... we keep upgrading our product we reserve the right to modify the product without natice in advance Abestorm Solutions INC Water Damage Series Add Berlin Tel 44 20 81243974 Email www abestorm com AbesTec 4000i Dehumidifier ...

Страница 2: ...er supply always grasp the plug and not the cord WARNING Risk of Electric shock hot surface rotating fan hazards Power off the unit and unplug from supply before opening the front cover for servicing or cleaning The unit must be connected to a grounded power supply The three prong plug should only be inserted into a matching outlet that is electrically grounded The cord should never be used with a...

Страница 3: ...nstead have a qualified electrician install the correct outlets This equipment should only be used on circuits that have a nominal rating of not above 120V The unit Should Be Handled Carefully Position the unit on a surface that is level and stable when running Do not throw drop or place the unit where it could tumble Rough handling of the unit could lead to damages that void the warranty It could...

Страница 4: ...ction is correct The green light will not illuminate if both the power cords are inserted into the same circuit or when using a single cord For maximum efficiency use both circuits while ensuring that the green light illuminates However the dehumidifier may run on one power cord if the second circuit is not available Plug into Circuit 1 When using a single power cable the dehumidifier operates at ...

Страница 5: ...activation Outlet to an outside location The Reactivation ducting MUST be connected to a reactivation outlet Ducting should not be longer than six meters 20 feet Set the ducting with the least number of bends that can be attained Tips The ducting should slope downwards away from the equipment Always duct the Reactivation Outlet preferably to an outdoor location Notice Sometimes water may collect i...

Страница 6: ...icle Maintenance For more detailed instructions visit www unipdry com WARNING RISK OF ELECTRIC SHOCK Disconnect the unit from the power supply before servicing or cleaning 9 10 WARNING Dust and contaminants exposes you to hazards The use of hand gloves and respirator mask is highly recommended If you realize that the product has been exposed to a possibly harmful contaminant clean thoroughly by di...

Страница 7: ...ter or any kind of cleaning solution Take caution not to damage the electronic sensors and lead wires Reattach the side panel Reattach the sensor cable inside the panel Thread the cable upwards over the zip tie and plug it in Install the screws and fasten sing fingers only starting from the top working downwards Once the screws are correctly started use a hand screw to tighten them lightly do not ...

Страница 8: ...WER FAILURE is not an error message When this message is displayed it indicates that the power supply was interrupted and then reestablished Use the MENU SELECTION key to clear the message Troubleshooting Display is Blank No Airflow Error Code E1 Error Code E4 Error Code LO Error Code HI Tripped GFCI Outlet or Breaker Cause Solution Poor Connection Power Outage Filter is dirty Air Inlet or Outlet ...

Страница 9: ...ntrol Specifications Power 115V 60HZ Amperages max 24Amperes Amperages at 80 60 RH Circuit 1 10 7 Circuit 1 10 8 Process air 395 CFM 65 CFM Reactivation air Water removal capacity at 80 F 60 RH 118 pints per day 55 8 L per day Weight Dimensions H W D 33 13 21 14 20 25 in With handle upright 42 250 in 84 15 53 7 51 4 cm With handle upright 107 3 cm 95 lbs 43 1 kg Air filter Safety F590 24 pk ETL li...

Страница 10: ...rtation charges 1 To gain the full advantage of the warranty the customer is expected to care for the unit including cleaning and routine maintenance 3 All the costs related to transporting the unit to a certified technician will be borne by the owner including ancillary charges such as wrapping labeling picking up the customer and palletizing 2 Reinstallation and removal of the unit will be done ...

Отзывы: