background image

Operating Relative Humidity Range: 

1%-40%

Amperage Usage:

 

4.41 Amps

Sound Level: 

58 dBa

Airflow :

210

 

CFM

COP: 

3.0 L/kWh

Power Supply: 

220V/60Hz

Dimensions LxWxH: 

540×295×440mm

Operating Temp. Range:

 

25-80

Refrigerant: 

R410A

Outlet Requirement:

 

15 Amp, 3 Prong, GFCI

Unit Weight: 

28kg

Operation

Transporting

Always keep the unit inside the space that you need to dry up, insert the hose into the 

drain or a large container, and switch it on. To reduce the time it takes to dry, ensure that 

all doors, windows, and other large openings are closed or sealed as the case may 

require. You should also demarcate and seal off the wet areas from the dry spaces.

Capacity: 

43L @ 26 ˚C , 60% RH

Warranty Registration

Prior to installation of the unit,write down the serial number and date of purchase. 

You will need this information if you need assistance in the future. The data label on 

the side of your unit has the necessary information.

Model Number: SLGR Elite

Serial Number:

Date of Number:

For additional questions concerning your dehumidifier, 

Contact your local installer or 

Contact Abestorm :

[email protected] or 44(20)81243974.

Electrical Supply

Power Supply: 

Outlet Requirement: 

Citcuit protector: 

WARNING:

Using a 220V outlet may cause serious injury from electric shock.

To reduce risk of injury:

                                   1. Always disconnect machine from electrical power before servicing

                                   2. Only plug unit into a gounded electrical cicuit

                                   3. Do not use an extension cord

                                   4. Do not use a plug adapter

3-Prong, GFCI

220V/50HZ

15Amp

Specifcations

The Abestorm® SLGR Elite sports a high impact resistant roto-molded casing that 

provides sufficient protection from possible damage when the unit is hit or when it falls. 

Remember to always place the unit on its base when moving it from location to location 

and when moving by vehicle or similar means. You may want to tip it upright if you want 

to make use of its handles when loading it to a trailer back.

Selecting the Location

• Place the Unit in an Upright Position.
• The location of the operation should be an enclosed area.
• The location should allow constant air circulation.
• The location should have power outlet at about 6 meters of the 
device as that is the length of the cord.
• Keep the Dehumidifier away from any moisture-laden air in the 
working area.

3

2

Содержание SLGR Elite

Страница 1: ...fier User sManual Note as we keep upgrading our product we reserve the right to modify the product without natice in advance Abestorm Solutions INC Water Damage Series Add Berlin Tel 44 20 81243974 Email www abestorm com ...

Страница 2: ...at can instant detect the room and provide instant feedback With a superior stacking and a heavy duty condensate pump These stackable dehumidifiers are the best drying system Read the operation and maintenance instructions carefully before using this unit Proper adherence to these instructions is essential to obtain maximum beneft from your Abestorm SLGR Elite dehumidifer It is designed to be used...

Страница 3: ...our local installer or Contact Abestorm sales Abestorm com or 44 20 81243974 Electrical Supply Power Supply Outlet Requirement Citcuit protector WARNING Using a 220V outlet may cause serious injury from electric shock To reduce risk of injury 1 Always disconnect machine from electrical power before servicing 2 Only plug unit into a gounded electrical cicuit 3 Do not use an extension cord 4 Do not ...

Страница 4: ...k or even to a container that can collect the discharged water Control Panel When the unit is plugged in you will see the Abestorm LOGO STARTUP Press the POWER button to turn the dehumidifier ON and OFF Press the PURGE button to purge the machine Press the MENU button to advance to the next screen or to enter a value Press the SET button to scroll through available values The machine displays when ...

Страница 5: ...7 6 ...

Страница 6: ...rt causes clogging in the system Instructions for use of filter 9 8 E1 Humidity Sensor or Communication Error Solution Check to ensure that the sensor wire is connected at both ends if no issues are visible the sensor may be faulty E4 Problem with Pump Solution Verify that the pump is properly installed and functioning If so unplug the unit for two minutes then restart Solution Increase the room t...

Страница 7: ...r back and pour a cup of 8oz of an antifreeze reagent with Propylene glycol Put it via the heat exchanger It will stream into the reservoir of the pump Avoid purging the solution from the unit 5 If filters are dirty they should be replaced if the unit is going to be stored for a long time This precaution will prevent microbial from growing on the filter Technical Description The unit a system of r...

Страница 8: ...y or the airflow is restricted 4 The front casing is not tied to the rear one I If the compressor runs with its air button turned off check if 1 The control board is defective AirMover The impeller causes the air to move If it is defective the whole assembly should be replaced 1 Remove the power cable from the power socket 2 Pull out the exhaust and the control board 3 Remove the impeller bracket ...

Страница 9: ...nit from the power source 2 Remove the housing at the top 3 Disconnect the float switch cables from their harness 4 Remove the screw that ties the bracket of the pump to the housing at the bottom 5 Remove the float switch from the bracket by unscrewing The pump is activated by the float safety switch when the water level in the condensate pump has risen too high The switch is also responsible for ...

Страница 10: ...r and palletizing 2 Reinstallation and removal of the unit will be done by the owner 4 The customer is also responsible for risks related to damage and loss while shipping If shipped customer is responsible for all risk of loss or damage 2 If there is a need for warranty service the customer should contact Abestorm Tech Support on to get an RA Return Authorization number 44 20 81243974 3 After you...

Страница 11: ...ALLATION OR DESIGN FAILURE TO FOLLOW INSTRUCTIONS LACK OF NORMAL CARE TAMPERING MISUSE OR ABUSE WHETHER ACCIDENTAL OR INTENTIONAL FIRE HURRICANE STORM DAMAGE 3 ANY COSTS DUE TO LOST PROFIT OR DELAY 5 ANY ADDITIONAL COSTS DUE TO CHANGES IN LAWS OR BUILDING CODES 4 FREEZING 6 FREIGHT CHARGES 7 CORROSION 8 CAUSE BEYOND CONTROL 9 FILTERS 10 CONSUMABLE PARTS INCLUDING BUT NOT LIMITED TO SWITCHES POWER ...

Отзывы: