Mistakes and Shortcomings

The equipment has been checked for normal function several times during the production process.
If the fault still occurs, please check the equipment according to the following list.

Warning
Electric shock is life-threatening!

Before performing any operation on the device, please unplug the power plug from 
the socket. Do not bypass any electrical safety devices!
In order to ensure the normal operation and trouble-free operation of the equipment, it 
must be cleaned and maintained regularly.

!

Problem

Cause

Device does not work.

The fuse is blown

The power plug 
is damaged.

Solution

Replace the damaged fuse and/or 
reopen the fuse. Be careful! The fuse 
does not need to be repaired, but it 
must be replaced at any time. In most 
cases, the fuse is triggered by a serious 
technical failure. Please authorized 
service personnel to replace each fuse!

Let certified personnel inspect the 
equipment

.

Loud noise.

Disconnect the power supply of the 
device and check whether the power 
plug and connecting cable are damaged

.

Plug the plug into the socket.

The connection 
parameters do not match 
the technical 
specifications.

Check the connection to the main line.
Connection parameters: 
110 V / 60Hz, 1.2A.

Even if the cleaning 
process has been 
completed, the odor 
pollution still persists with 
the same intensity.

Send the equipment to a certified 
professional workshop for repair

.

This device is placed in 
an uneven place

.

Reactor damage.

Power is not turned on.

Damage to the fan and/or 
its bearings

.

Place the device on a flat, solid, dry 
surface

.

Содержание OZ-G2000

Страница 1: ... G2000 Abestorm Add 8605 SANTA MONlCA BLVD 79525 WEST HOLLYWOOD California 90069 USA E mail sales abestorm com Note as we keep upgrading our product we reserve the right to modify the product without notice in advance ...

Страница 2: ...Table of Contents Device Description Operation Mistakes and Shortcomings Maintenance Transportation and Storage Technical Annex Electrical Wiring Diagram Limited Warranty 01 02 04 05 06 07 08 09 ...

Страница 3: ... that energy breaks the diatomic oxygen molecule into two single oxygen atoms in the form of free radicals The OZ G2000 of the Abestorm series uses oxygen in the surrounding air as a molecular compound Atomic oxygen recombines with oxygen molecules A to form ozone Due to their metastable bonds unoxidized OZ G2000 molecules will also decompose into oxygen after a period of time without leaving harm...

Страница 4: ...vice The display panel will light up The cleaning cycle will begin immediately Once the preset time has passed the Abestorm OZ G2000 machine will automatically shut down 1 2 3 4 5 1 2 3 1 1 2 Generally OZ G2000 will automatically decompose into oxygen in about an hour If a person stays indoors for a long time it is generally subject to not being able to smell the strong OZ G2000 smell Overall Work...

Страница 5: ...ning the processing time Type of Smell The treatment time is in min 3 Room size 30 m 15 20 20 40 40 40 240 360 360 3 3 30 m Room size 60 m 30 40 40 60 60 60 480 720 720 Disinfectant Car Interior From Animals Cooking and Waste Burning Chemical The Musty Smell After Water Damage Secondary Effects of a Burning Smell and Organic Matter Amine Amide urea Open chain Hydrocarbon Compound e g Butyric Acid ...

Страница 6: ...fuse does not need to be repaired but it must be replaced at any time In most cases the fuse is triggered by a serious technical failure Please authorized service personnel to replace each fuse Let certified personnel inspect the equipment Loud noise Disconnect the power supply of the device and check whether the power plug and connecting cable are damaged Plug the plug into the socket The connect...

Страница 7: ...nt Regardless of the operating conditions described you should perform maintenance if one or more of the following signs appear Severely polluted soft magnetic stickers The substances produced during the OZ G2000 production process gradually disappear The noise level increases when the fan is running Dirty electrodes identifiable by hissing sound House Cleaning Clean the case with a soft damp lint...

Страница 8: ...the Abestorm OZ G2000 in a dry place to avoid the influence of bad weather and cover it to protect it from invasive dust When the equipment is not in use always disconnect the power supply Clean Electrode Ensure that the equipment is protected from splash water Make sure that there are no obstructions at the air inlet and outlet Make sure to place the device on a dry and vibration free surface If ...

Страница 9: ...Operating Temperature Sound Pressure Level Service Life Size For Dimensions L W H Minimum Distance From Walls and Other Objects Top a Rear b Sides c Front d Value 110V 60HZ 1 2A 55 130 CFM 220 CMH 15 000 mg h 65 db 25 000 h 1 600 sq ft 10 2 x 6 9 x 8 7 in 20 in 20 in 20 in 20 in Airflow ...

Страница 10: ...8 Electrical Wiring Diagram Ozone Generator N T GRN PCB Blue RED TRANSFORMER Display PERIOD FAN CLOCK POWER OZONE RUN CAP ...

Страница 11: ...pair How to Request Warranty Services Our customer service will address your issue in 24 hours To obtain the benefit of this warranty please leave your message online www abestorm com or send an email to sales abestorm com All warranty benefits apply to the original owner only Warranty cannot be transferred or assigned Abestorm Warranty Steps 1 2 3 4 5 6 www abestorm com Abestorm Abestorm sales ab...

Страница 12: ... is replaced while under warranty the applicable warranty period shall not be extended beyond the original warranty time period Any dishonesty or fraud in connection with Abestorm warranty thoroughly voids all warranty policies Abestorm expressly reserves the right to pursue legal action in the event of dishonesty fraud or attempted fraud The foregoing shall constitute the total liability of selle...

Страница 13: ......

Отзывы: