Troubleshooting Guide
PHT 2004 ULX Controls
(ULXT models)
Filter Cycle does not operate
– Adjust the temperature set point to be within 2°F of the actual water temperature. If the water temperature
creeps 2°F higher than the set temperature, the system will shut off to allow the water to cool. When the
water cools down to the desired set point, filtration will resume. Proper ventilation of the equipment will
minimize this interruption.
Ground Fault Interrupter Trips
– Check if it does it only when heat turns on, if so, check element by removing the power to the element
terminal and turn the heat on. If it only faults when the element is connected with power, the element has
a ground fault and must be replaced.
– This can be done with the pump(s), blower, ozonator or any other peripheral equipment as a process of
elimination to see where the fault may be.
– Be sure that the neutral on the GFCI has been wired properly in the main panel.
General
– All connections should be checked that they are secure.
– Always exercise general electrical common sense for safety.