LOW LEVEL PROGRAMMING
It is possible to configure various systems operating parameters from the keypad. This is normally done at
Gecko factory or by the spa manufacturer, but may be done at anytime. The configuration will be kept into an
EEPROM memory. To program these system parameters, the Light switch must be held for 20 seconds. After
this time, the first parameter will be displayed (see below). For each parameter, use the Plus/Minus keys to
modify its value. Light key is used to accept the new value and switch to the next parameter. The display
returns to the normal display when there is no more parameter to change. There are four (4) low-level
programmable parameters:
1.
Input current mode configuration:
Display: HC or LC
Value:
HC = High current breaker (default)
LC = Low current breaker
2.
Pump speed configuration:
Display: SPx (ex. SP1)
Value x: 1 = 1 speed
2 = 2 speeds (default)
3.
Temperature display units configuration:
Display: Tux (TuC)
Value x: F = Temperature display in Fahrenheit units (default)
C = Temperature display in Celsius units.
4.
Light intensities configuration:
Display: L1 or L2
Value:
L1 = One intensity
L2 = Two intensities (default)
NOTE: The system must be configured for 1 light intensity when a Colour Kinetic LED module is used.
24
PA C I F I C H O T T U B S O W N E R ’ S M A N U A L
Содержание Pacific 2004
Страница 54: ...55 PACIFIC HOT TUBS OWNER S MANUAL PHT 1000 PHT 2002 ...
Страница 55: ...56 PACIFIC HOT TUBS OWNER S MANUAL PHT 1000 PHT 2002 ...
Страница 56: ...57 PACIFIC HOT TUBS OWNER S MANUAL LXT Models equipped with Aqua Stealth ...
Страница 57: ...58 PACIFIC HOT TUBS OWNER S MANUAL LXT Models ...
Страница 58: ...59 PACIFIC HOT TUBS OWNER S MANUAL ULXT Model ...