VA Master FAM540
METAL CONE VARIABLE AREA FLOWMETER | OI/FAM540-EN REV. E
17
Table 3
: Analoganzeiger mit Grenzwertgeber
Model FAM54xB/C/Dx
Type of protection: flameproof enclosure, dust explosion protection.
Order
code
*
Marking Terminals
Electrical
values
T
amb
−
20 °C to (
−
50 °C to )
Temp. class
T
medium
Maximum
Insulation
A9
ATEX:
II 1/2 G Ex db h IIC T6 ... T1 Ga/Gb
II 2 D Ex h tb IIIC T85°C ... Tmedium Db
IECEx:
Ex db h IIC T6 ... T1 Ga/Gb
Ex h tb IIIC T85°C ... Tmedium Db
41 / 42
**
51 / 52
**
U
max
= 16 V
I
max
= 25 mA
P
max
= 64 mW
40 °C
T1
440 °C
No
40 °C
T1
375 °C
yes
40 °C
T1
260 °C
yes
50 °C
T1
300 °C
yes
50 °C
T2
290 °C
yes
50 °C
T2
220°C
yes
60 °C
T2
320 °C
No
60 °C
T2
230 °C
yes
60 °C
T3
170 °C
yes
70 °C
T3
195 °C
No
70 °C
T3
150 °C
yes
70 °C
T4
130 °C
yes
70 °C
T5
95 °C
yes
60 °C
T6
80 °C
yes
No
41 / 42
**
51 / 52
**
U
max
= 16 V
I
max
= 52 mA
P
max
= 169 mW
40 °C
T1
440 °C
40 °C
T1
375 °C
yes
40 °C
T1
260 °C
yes
50 °C
T1
300 °C
yes
50 °C
T2
290 °C
yes
50 °C
T2
220°C
yes
60 °C
T2
320 °C
No
60 °C
T2
230 °C
yes
60 °C
T3
170 °C
yes
70 °C
T3
195 °C
No
70 °C
T3
150 °C
yes
70 °C
T4
130 °C
yes
60 °C
T5
60 °C
yes
50 °C
T5
90 °C
No
40 °C
T6
60 °C
yes
41 / 42
**
51 / 52
**
U
max
= 16 V
I
max
= 76 mA
P
max
= 242 mW
40 °C
T1
440 °C
No
40 °C
T1
310 °C
yes
40 °C
T2
190 °C
yes
50 °C
T2
340 °C
No
50 °C
T2
230 °C
yes
60 °C
T2
230°C
No
60 °C
T3
160 °C
yes
70 °C
T4
120 °C
No
70 °C
T4
100 °C
yes
40 °C
T5
60 °C
yes
30 °C
T6
30 °C
yes
* Order code ‘Explosion protection and approvals’ (versions 9, 10); refer to
Ordering information in the data sheet
on page 62.
** for connection to a non-intrinsically safe circuit If the device is to be operated subsequently with type of protection "intrinsically safe", then U
max
= 60 V may
not be exceeded.