TZIDC-110, TZIDC-120
DIGITAL POSITIONER | OI/TZIDC-110/TZIDC-120-EN REV. H
… 2 Use in potentially explosive atmospheres
TZIDC-110 – Ex relevant specification
Note
The values indicated here are taken from the respective
certificates. Always observe the specifications and supplements
in the explosion protection certificates.
ATEX / UKEX – ‘Ex i’ type of protection
Ex-marking
Ex marking
Marking
II 2 G Ex ia IIC T6, T4…T1 Gb
II 2 G Ex ib IIC T6, T4 ...T1 Gb
Type examination
certificate (ATEX)
TÜV 04 ATEX 2702 X
Certificate (UKEX)
EMA22UKEX0032X
Type
Intrinsically safe equipment
Device class
II 2G
Standards
EN 60079-0, EN 60079-11
Temperature data
Temperature class
Ambient temperature Ta
T4 to T1
−
40 to 85 °C
T6
−
40 to 40 °C*
Electric Data
With the ‘Intrinsic safety Ex i IIC’ type of protection, only for
connection to a certified FISCO power supply unit or a barrier,
i.e., a power supply unit with maximum values according to the
following tables:
Connection to a barrier or power supply unit
Current circuit (terminal)
Electrical information (maximum values)
Signal circuit
(+11 /
−12)
Voltage:
24 V
Current:
250 mA
Power:
1.2 w
L
i
, C
i
Negligible
Characteristic
curve:
rectangular
Connection to a FISCO power supply unit
Current circuit (terminal)
Electrical information (maximum values)
Signal circuit
(+11 /
−12)
Voltage:
17.5 V
17.5 V
Current:
380 mA
360 mA
Power:
5.32 w
2.52 W
L
i
, C
i
Negligible
Characteristic
curve:
rectangular
trapezoidal
Current circuit (terminal) Electrical information (maximum values)
Feedback on the actuator
position using proximity
switches, (Pepperl & Fuchs
SJ2-SN)
(Limit1: +51 / −52),
(Limit2: +41 / −42)
For maximum values, see EU-Type examination
certificate PTB 00 ATEX 2049 X Pepperl & Fuchs
Type 2 proximity switches
Local communication
interface (LCI)
Only for connection to a programming device
using an ABB LCI adapter (Um ≤ 30 V DC) outside
the hazardous area.
Special conditions
• Permissible for the ‘Natural gas version’ only:
– The positioner TZIDC-110 may be operated as a power
supply only with gases of Group IIA and temperature class
T1 outdoors or inside of buildings with sufficient
ventilation.
– The supplied gas must be free of air and oxygen to
prevent the forming of a hazardous atmosphere.
– Exhaust gas must always be discharged outside.
• The equipment may only be used as a II 2D type device
TZIDC-110 in areas where the level of mechanical danger is
"low".
• For TZIDC-110 electrostatic charging caused by propagating
brush discharge should be prevented when the device is used
for applications involving combustible dust.
• For devices that are operated in an intrinsically safe manner,
cable and wire entries should be used that meet the
requirements of EN 60079-11 for Category II 2G as well as the
ambient temperature range.
• The ‘local communication interface’ (LCI) of the TZIDC-110
may only be operated at U
m
≤
30 V DC outside the hazardous
area.
Содержание TZIDC-110
Страница 31: ...TZIDC 110 TZIDC 120 DIGITAL POSITIONER OI TZIDC 110 TZIDC 120 EN REV H 31 Page 2 of 5 ...
Страница 33: ...TZIDC 110 TZIDC 120 DIGITAL POSITIONER OI TZIDC 110 TZIDC 120 EN REV H 33 Page 4 of 5 ...
Страница 66: ...66 TZIDC 110 TZIDC 120 DIGITAL POSITIONER OI TZIDC 110 TZIDC 120 EN REV H Notes ...
Страница 67: ...TZIDC 110 TZIDC 120 DIGITAL POSITIONER OI TZIDC 110 TZIDC 120 EN REV H 67 Notes ...