6 Troubleshooting
6.1 Malfunctions when starting
Sluggish start-up
Possible causes
Elimination
Turbochar-
ger
Turbocharger contaminated
Clean it
Damaged bearing
Contact an ABB Turbocharging
Service Station
Rubbing rotor
Foreign object in turbocharger
Vibrations
Possible causes
Elimination
Turbochar-
ger
Rotor unbalance
Contact an ABB Turbocharging
Service Station
Damaged turbine or com-
pressor
Damaged bearing
Rubbing of rotating parts
Normal behaviour, no malfunction
Turbochar-
ger
Minor uniform wear around the periphery of rotor components,
caused by slight local rubbing of adjacent components, is per-
missible. The compressor blades and turbine blades are then
shortened somewhat. Certain tolerances must be observed to
avoid a significant loss of efficiency.
¡
If there is any doubt about the extent of rubbing, then an
ABB Turbocharging Service Station must be contacted.
¡
Have a dimension check carried out by an ABB Turbochar-
ging Service Station.
6.2 Surging of the turbocharger
Turbocharger surging
Possible causes
Elimination
Engine
Guard in front of the tur-
bocharger is contaminated
or damaged
Clean / replace it
Turbocharger Filter silencer or diffuser
contaminated
Clean it
Heavy deposits of dirt in the
turbine or nozzle ring