2TLC172121M0201, rev. A
6
www.abb.com/lowvoltage
2011-09-20
3 Connections
NB: The connection cable cross section area is 0.34 mm
2
and cable length is 150 mm.
Caution!
The connection cables should not be extended as longer cables increase the risk for electrical
interference.
Warning!
The information channel output shall
never
be used for the safety purpose(s).
The connection cables are not monitored and must therefore be installed within the same physical enclosure as the
safety device to maintain the highest safety level (fault exclusion, refer to EN ISO 13849-2:2003 Annex D).
The safety adaptor shall
not
be used for purposes other than intended. All loading or tampering with the device can
lead to serious risk of life.
5-pole connection cables:
1 ) Brown:
+24 VDC
2 ) White:
Dynamic signal input
3 ) Blue:
0 VDC
4 ) Black:
Dynamic signal output
5 ) Grey:
Information