background image

 

 

2TLC172121M0201, rev. A 

www.abb.com/lowvoltage 

2011-09-20  

4  Installation and maintenance  

Installation precautions 

The unit must first attach to the M20 connector (Tina 2A) before the safety loops are connected to the sensor.  

 

Warning!

 All the safety functions must be tested before starting up the system. 

Maintenance 

  Warning!  

The safety functions and the mechanics shall be tested regularly, at least once every year to confirm that all the 
safety functions are working properly (EN 62061:2005). 

In case of breakdown or damage to the product, contact the nearest ABB/Jokab Safety Service Office or reseller. 
Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, 
impairing the safety of the device which in turn could lead to serious injury to personnel. 

Testing of the safety functions 

Make sure the safety unit is working properly by following these steps: 

  Interrupt the dynamic safety circuit before this unit. The LED should flash between green and red.  

  Interrupt protection. The LED should flash between green and red.  

  The LED will light green when protection is OK and if the safety circuit(s) before this unit is not interrupted. 

Troubleshooting 

LED indication 

Expected causes of faults 

Checking and measures to take 

Lights red 

24 VDC input to pin-2 (no dynamic signal) 

Check if there is 24 VDC to input (pin-2). If 
Yes, check cable or unit before and fix it. 

No lights 

Loss of power supply 

Check 24 VDC / 0 VDC power supply 

Lights green (but no dynamic output 
detected) 

Defected dynamic signal input to unit 
(asymmetric pulses) 

Check the dynamic input or the unit before 

Weak lights or red and green lights at the 
same time 

The unit is defect 

The unit needs to be replaced. Contact 
ABB/Jokab Safety. 

 Warning! 

Replace defected unit with a new one and never bypass the safety circuit using Tina 1A or any other 

solution.

 

Содержание Tina 2B

Страница 1: ...ABB AB Jokab Safety Varlabergsv gen 11 SE 434 39 Kungsbacka Sweden www abb com lowvoltage Original instructions Tina 2A B Adaptor unit...

Страница 2: ...FETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete deter...

Страница 3: ...iew 5 General description 5 Safety regulations 5 3 Connections 6 Connection examples 7 4 Installation and maintenance 8 Installation precautions 8 Maintenance 8 Testing of the safety functions 8 Troub...

Страница 4: ...of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of machine safety Special notes Pay attention to the following special notes in the document Warn...

Страница 5: ...ty sensors without an M20 threaded connector The Tina2A B adaptor unit is intended for use in safety circuits in accordance with EN 60204 1 Warning In order to maintain the highest safety level and re...

Страница 6: ...used for the safety purpose s The connection cables are not monitored and must therefore be installed within the same physical enclosure as the safety device to maintain the highest safety level faul...

Страница 7: ...2TLC172121M0201 rev A 7 www abb com lowvoltage 2011 09 20 Connection examples Caution All cable colours according to ABB Jokab Safety standard cables...

Страница 8: ...ions Make sure the safety unit is working properly by following these steps Interrupt the dynamic safety circuit before this unit The LED should flash between green and red Interrupt protection The LE...

Страница 9: ...namic signal Dynamic signal input does not exist i e the safety circuit is interrupted before this unit 24 VDC A constant 24 VDC signal is applied high H 0 VDC The pin is connected to 0 VDC low L The...

Страница 10: ...d 13 volt RMS Dynamic output between 9 and 13 volt RMS Information output 23 VDC General Protection class IP67 Ambient temperature Storage 30 70 C Operation 10 55 C Humidity range 35 to 85 with no ici...

Страница 11: ...2TLC172121M0201 rev A 11 www abb com lowvoltage 2011 09 20 Dimensions Tina 2A Tina 2B NB All measurements in millimetres...

Страница 12: ...to compile the technical file Lars Magnus Felth ABB AB JOKAB SAFETY Varlabergsv gen 11 SE 434 39 Kungsbacka Sweden Product Certificate Serialnumber Non contact safety sensor Eden Adam Eva E C EC 44 2...

Отзывы: