4

Safety information

D

eath or severe electrical shock can occur

In no case should the line current circuit be interrupted with the regulator or transformer energized. Do not remove auxiliary 
current transformers without shorting the current inputs.

Exercise care during installation, operation and maintenance procedures

The equipment described in this manual contains voltages high enough to cause serious injury or death. Only qualified per-
sonnel should install, operate, test, and maintain this equipment. Be sure that all personnel safety procedures are carefully 
followed. Exercise due care when operating or servicing alone.

Remove Fuses Before Service

Содержание TCC300

Страница 1: ...Voltage Reduction Steps Shortcuts arrows 4 SETP Access to the Setpoints screens 5 MNTR Access to the Monitoring screens 6 ENT UTL Push button Access to the Utilities screens and enter button 7 CNFG A...

Страница 2: ...two periodic flashes indicates Level 2 Voltage Reduction Continuous illumination and three periodic flashes indicates Level 3 Voltage Reduction MANUAL LED Indicates automatic control is disabled and i...

Страница 3: ...13 14 15 16 17 18 19 20 21 22 23 24 Fuse Amp Voltage Input Polarity Load Current Return See Note 2 Voltage Input Return See Note 2 Load Current Polarity 0 2 A Circulating Current Polarity 0 2A Circul...

Страница 4: ...ng the current inputs Exercise care during installation operation and maintenance procedures The equipment described in this manual contains voltages high enough to cause serious injury or death Only...

Страница 5: ...l xx Min Demand Load Voltage xxx x Volts Demand Pri Current xxx x Amps Demand Pri Watts x xx MW Demand Pri VArs x xx MVArs Demand Pri VA x xx MVA Demand Interval xx Min Min Load Voltage E x x Volts Ma...

Страница 6: ...Power Flow Fwd 1 Bandcenter Fwd xxx x Volts LDC X Fwd x Volts Bandwidth Fwd x x Volts LDC Z Fwd x Volts LDC R Fwd x Volts With LDC R X With LDC Z Definite Inverse Delay Fwd xx Sec Bandcenter Rev xxx...

Страница 7: ...er Display Option SINGLE_PHASE Fast Volt Recovery disable Fast Volt R Setting x x V Regulator Type TYPE A Output Selection CONTINUOUS Output Pulse X X Sec Low Current Block disable Tap Limits ENABLED...

Страница 8: ...KT DVAR2 Sensitivity x x DVAR2 Reac I Lmt xxx mA DVAR2 I Ratio x xx Paralleling Type MASTER FOLLOWER MASTER FOLLOWER NONE Paralleling Address xx Num Devices x T P R Timeout xxxxx ms Breaker Option xxx...

Страница 9: ...Validation disable Substation Address DNP x Feeder Address DNP x Comm Address DNP 1 Mdbus 1 Baud Rate 9600 Parity NONE Stop Bits ONE STOPBIT Sync Time 2 mS Output Pulse 1 5 Sec Comm Access Security d...

Страница 10: ...S Coefficient 8192 X Circ Cal Coefficien 32767 X Circ Sin Coefficient 0 X Circ Cos Coefficient 8192 X LED Scroll Test Press ENT to begin Input Test Press ENT to Begin Output Test Press ENT to test But...

Страница 11: ...11...

Страница 12: ...ht 2016 ABB All rights reserved Contact us ABB Inc EPMV Distribution Automation 4300 Coral Ridge Drive Coral Springs FL 33065 USA Phone 1 800 523 2620 Phone 1 954 752 6700 Fax 1 954 345 5329 www abb c...

Отзывы: