Menu screens

UTILITIES

COMM       MNTR

Bias Voltage    

Status/Test Mode

Load Voltage

XXX.X Volts

Voltage Offset

X

Volt Cal Coefficient

32767 X

Volt RMS Coefficient

32762 X

Control Load I

x.x mA   Lag/Lead

Curr Cal Coefficient

32767 X

Power Factor

X.XXX  Lag/Lead

I Sin Coefficient

0  X

I Cos  Coefficient

8192  X

Motor Current

x.xx  mA

Mtr Cal. Coefficient

8192  X

Mtr Sin Coefficient

0  X

Mtr Cos Coefficient

8192  X

Calibration/Test

Mtr RMS Coefficient

8192  X

Circ Cal. Coefficien

32767  X

Circ Sin Coefficient

0  X

Circ Cos Coefficient

8192  X

LED Scroll Test

Press ENT to begin

Input Test

Press ENT to Begin

Output Test

Press ENT to test

Button Input Test

Press ENT to Begin

Change Src Input   

press ENTER.

Watchdog resets:  X

Total resets:  X

Clear reset counters

Press ENT to begin

X1 Duration

0 ms,  Avg:   0 ms

Alarm Activity

Press ENT to Begin

About

Serial Number

xxxxx

Firmware Version

D-0214VXX.XX.XX

EE Checksum

XXXXXX

Last Loaded File CRC

XXX

Hardware Number

1

Complete customer documentation is available in the product pages that can be accessed through 

www.abb.com

Содержание TCC300

Страница 1: ...Voltage Reduction Steps Shortcuts arrows 4 SETP Access to the Setpoints screens 5 MNTR Access to the Monitoring screens 6 ENT UTL Push button Access to the Utilities screens and enter button 7 CNFG A...

Страница 2: ...two periodic flashes indicates Level 2 Voltage Reduction Continuous illumination and three periodic flashes indicates Level 3 Voltage Reduction MANUAL LED Indicates automatic control is disabled and i...

Страница 3: ...13 14 15 16 17 18 19 20 21 22 23 24 Fuse Amp Voltage Input Polarity Load Current Return See Note 2 Voltage Input Return See Note 2 Load Current Polarity 0 2 A Circulating Current Polarity 0 2A Circul...

Страница 4: ...ng the current inputs Exercise care during installation operation and maintenance procedures The equipment described in this manual contains voltages high enough to cause serious injury or death Only...

Страница 5: ...l xx Min Demand Load Voltage xxx x Volts Demand Pri Current xxx x Amps Demand Pri Watts x xx MW Demand Pri VArs x xx MVArs Demand Pri VA x xx MVA Demand Interval xx Min Min Load Voltage E x x Volts Ma...

Страница 6: ...Power Flow Fwd 1 Bandcenter Fwd xxx x Volts LDC X Fwd x Volts Bandwidth Fwd x x Volts LDC Z Fwd x Volts LDC R Fwd x Volts With LDC R X With LDC Z Definite Inverse Delay Fwd xx Sec Bandcenter Rev xxx...

Страница 7: ...er Display Option SINGLE_PHASE Fast Volt Recovery disable Fast Volt R Setting x x V Regulator Type TYPE A Output Selection CONTINUOUS Output Pulse X X Sec Low Current Block disable Tap Limits ENABLED...

Страница 8: ...KT DVAR2 Sensitivity x x DVAR2 Reac I Lmt xxx mA DVAR2 I Ratio x xx Paralleling Type MASTER FOLLOWER MASTER FOLLOWER NONE Paralleling Address xx Num Devices x T P R Timeout xxxxx ms Breaker Option xxx...

Страница 9: ...Validation disable Substation Address DNP x Feeder Address DNP x Comm Address DNP 1 Mdbus 1 Baud Rate 9600 Parity NONE Stop Bits ONE STOPBIT Sync Time 2 mS Output Pulse 1 5 Sec Comm Access Security d...

Страница 10: ...S Coefficient 8192 X Circ Cal Coefficien 32767 X Circ Sin Coefficient 0 X Circ Cos Coefficient 8192 X LED Scroll Test Press ENT to begin Input Test Press ENT to Begin Output Test Press ENT to test But...

Страница 11: ...11...

Страница 12: ...ht 2016 ABB All rights reserved Contact us ABB Inc EPMV Distribution Automation 4300 Coral Ridge Drive Coral Springs FL 33065 USA Phone 1 800 523 2620 Phone 1 954 752 6700 Fax 1 954 345 5329 www abb c...

Отзывы: