Important information in advance

4

Thermal Mass Flowmeter FMT400-VTS, FMT400-VTCS (Sensyflow VT-S/VT-CS)

42/14-36 EN

1   Important information in advance

Symbols

In order that you can make the best use of this document and to ensure safety during commissioning, operation
and maintenance of the equipment, please note the following explanation of the symbols used.

Explanation of the symbols used.

As well as the instructions in this document, you must also follow the generally applicable accident prevention
and safety regulations.

If the information in this document is insufficient in any situation, please contact our service department, who will
be happy to help you.

Please read this document carefully before installation and commissioning. 

In case of 
questions

If you cannot find any information concerning technical questions or malfunctions in these operating instruction,
please apply to one of our external service points or contact our technical user assistance hotline directly. For
all questions concerning the measuring system, please have the calibration certificate readily at hand.

Symbol

Signal Word

Definitions

DANGER

DANGER indicates an imminently hazardous situation which, if not avoided, 
will result in death or serious injury.
(High level of risk.)

WARNING

WARNING indicates a potentially hazardous situation which, if not avoided, 
could result in death or serious injury.
(Medium level of risk.)

CAUTION

CAUTION indicates a potentially hazardous situation which, if not avoided, 
could result in minor or moderate injury.
(Low level of risk.)

NOTICE

NOTICE indicates a potentially harmful situation which, if not avoided, 
may result in damage of the product itself or of adjacent objects.
(Damage to property)

IMPORTANT

IMPORTANT indicates useful hints or other special information which, if not 
observed, could lead to a decline in operating convenience or affect the 
functionality. 
(Does not indicate a dangerous or harmful situation.)

Sensyflow Hotline

Tel: 

+49 6023 92-3597 or -3267

Fax: 

+49 6023 92-3210

E-mail: [email protected]

Содержание Sensyflow FMT400-VTS

Страница 1: ...Operating instruction 42 14 36 EN Thermal Mass Flowmeter FMT400 VTS FMT400 VTCS Sensyflow VT S VT CS for gases compact configuration...

Страница 2: ...ducts GmbH Borsigstra e 2 63755 Alzenau GERMANY Tel 49 800 1114411 Fax 49 800 1114444 CCC support deapr de abb com Copyright 2006 by ABB Automation Products GmbH We reserve the right to technical amen...

Страница 3: ...or process engineering dimensions in mm 15 4 6 Weld on adapter 16 4 6 1 Weld on adapter for FMT400 VTS Sensyflow VT S transducer 16 4 6 2 Pipe component and weld on adapter with ball valve 17 4 7 Inte...

Страница 4: ...ice points or contact our technical user assistance hotline directly For all questions concerning the measuring system please have the calibration certificate readily at hand Symbol Signal Word Defini...

Страница 5: ...ertified and delivered in a safe condition To maintain this state and guarantee hazard free operation all safety instructions in this manual headed by DANGER WARNING CAUTION or NOTICE must be observed...

Страница 6: ...use in potentially explosive areas Only FMT400 VTS is available in a version authorized for use in zone 2 zone 22 These devices come supplied with an EU declaration of conformity ATEX For devices aut...

Страница 7: ...xious substances always rinse the pipes carefully When working on the pipes observe the applicable regulations for the prevention of accidents Do not use damaged pipe components or transducers Such un...

Страница 8: ...o the pipe Make sure that the sensor unit is not damaged Screw the transducer to the flange of the insertion pipe Evenly fasten the screws with the appropriate torque Torque for the screws supplied 87...

Страница 9: ...ects The measuring systems consist of only the 2 components detecting element and pipe component Fig 3 1 and Fig 3 2 show a schematic representation of the measuring systems FMT400 VTS process version...

Страница 10: ...er detecting element The detecting element which is designed as a plug in sensor contains apart from the sensor unit the completely cast transmitter switching unit installed in the connection head Thi...

Страница 11: ...ntion to the flow direction 4 Have the recommended input and output lengths been complied with 5 Is the installation between detecting element and pipe component correctly done 6 Are the used sealings...

Страница 12: ...pe lengths are used as steadying run lengths their length de pends on the type of the inlet run disturbance Recommended steadying lengths according to DIN EN ISO 5167 1 To achieve the stated measuring...

Страница 13: ...consult the DKD Calibration Department of ABB Automation Products GmbH at Alzenau An on site adjustment is also possible if reference flow values are precisely known by entering a calibration factor T...

Страница 14: ...the type 1 pipe component intermediate flange version with ball valve and a nominal width DN 200 ANSI 8 transducers with a length of 425 mm must be used 1 Centering pin 1 The flow direction must agre...

Страница 15: ...115 B4 58 269 263 28 5 115 600 486 DN 40 94 43 1 88 150 860 731 DN 50 109 54 5 102 165 1000 837 DN 80 144 82 5 138 DN 100 170 107 1 162 DN 150 226 159 3 218 450 DN 200 293 206 5 285 350 431 425 700 7...

Страница 16: ...erance 2 3 The centering pin of the adapter must be aligned in flow direction to the pipe axis at outlet run length behind measuring point 4 After welding the free passage for inserting the transducer...

Страница 17: ...ansducer and fasten it Prior to dismounting the transducer always check that the pipe is depressurized or that the pressure in the pipe is low enough to ensure safe dismounting Only then undo the 4 sc...

Страница 18: ...uring operation with virtually no gas escaping from the system It is recommended to use the hot tap fitting for measurements in main conduits e g compressed air systems or for measuring points which o...

Страница 19: ...ted hot tap fitting 4 7 2 Mounting the wafer flange version Fig 4 6 left shows the wafer flange version of the hot tap fitting mounted in the pipeline in disassembly position i e the guide tube is in...

Страница 20: ...d degree of shrinkage for welding The distance h from the upper edge of the flange on the fitting to the pipe central axis must be within a tolerance of 2 mm in measuring position Maintain the right a...

Страница 21: ...s to attach them to the special screws Fig 4 10 Rotate the Sensyflow transducer into measuring position using the lock nut Fig 4 10 The lower edge of the lock nut indicates the current position of the...

Страница 22: ...t ventilation is provided WARNING If when releasing the mounting screws you notice a large amount of gas escaping the activities must be stopped and screws retightened Check whether the fitting is act...

Страница 23: ...ransducers see chapter 4 7 5 To disassemble the guide tube release the 4 hex head screws on the lock nut Fig 4 8 and remove the guide tube Clean parts if necessary Replace the two internal Viton 36 x...

Страница 24: ...DN 25 DN 40 DN 50 DN 80 Standard measuring ranges 0 1 6 160 kg h 0 4 430 kg h 0 7 700 kg h 0 17 1700 kg h Standard measuring ranges 0 1 6 160 kg h 0 4 430 kg h 0 7 700 kg h 0 17 1700 kg h Standard me...

Страница 25: ...e transducers in the pipe components Select the gaskets in accordance with the connection standard used Pipe component hygienic version with FG flange FG 1 PN10 Transducer DN L L1 L2 D F 25 175 133 42...

Страница 26: ...ble e g 4 x 1 mm2 is required to connect the detector 2 Remove the connecting head cap of the detector by undoing the 4 screws 3 Connect the four wires to the terminal of the detector electronic unit...

Страница 27: ...tronics Connecting Connecting power supply 24 V Step Action 1 Check whether the voltage specified on the type plate matches the supply voltage 2 Use a power supply line with sufficient dimensions and...

Страница 28: ...ns voltage After power on the device is automatically on Step Check 1 Is the unit securely fastened 2 Are the electrical signal control and interface cable laid and connected correctly 3 Do the operat...

Страница 29: ...possible in case of fault The following settings will be possible in case of fault MIN 3 5 mA MAX 22 5 mA Notice The standard setting in case of fault is 0 20 mA for MAX and 4 20 mA for MIN These sett...

Страница 30: ...e under unfavorable conditions after transport under unfavorable conditions 1 Switch off the supply voltage 2 Remove the detector from the pipe component or weld on adapter make sure that the pipe is...

Страница 31: ...up to 3000 mm qmin qmax 0 1 6 160 0 4 430 0 7 700 0 17 1 700 0 30 3 000 0 80 8 000 0 130 13 000 0 27 000 2 700 000 qmin qmax 0 1 6 160 0 4 430 0 7 700 0 17 1 700 square ducts and larger diameters on...

Страница 32: ...dent on nominal size Material standard 1 4571 Ceramics stainless steel e g 1 4301 Process connection standard Flange acc to EN 1092 1 form B1 PN 40 or ANSI B 16 5 150 300 lbs Pipe fitting S acc to DIN...

Страница 33: ...absorbing material e g foam rubber The thickness of the shock absorber should be in accordance with the device weight and the type of shipment The box must be handled with care and has to be labeled...

Страница 34: ...34 Thermal Mass Flowmeter FMT400 VTS FMT400 VTCS Sensyflow VT S VT CS 42 14 36 EN 12 Declarations of conformity 12 1 Thermal Mass Flowmeter FMT400 VTS Sensyflow VT S 12 2 Declaration of conformity FM...

Страница 35: ...55 Alzenau Germany Tel 49 551 905 534 Fax 49 551 905 555 CCC support deapr de abb com ABB Inc 125 E County Line Road Warminster PA 18974 USA Tel 1 215 674 6000 Fax 1 215 674 7183 ABB has Sales Custome...

Отзывы: