Function

IEC 61850

A

B

C

 

CE01

CE02

CE03

Sequence current measurement

CSMSQI

1

1

1

Residual current measurement

RESCMMXU

1

1

1

Three-phase voltage measurement

VMMXU

1

1 (2)

13)

1

Sequence voltage measurement

VSMSQI

1

1 (2)

13)

1

Three-phase power and energy measurement

PEMMXU

1

1

1

Frequency measurement

FMMXU

1

1

1

Load profile

LDPMSTA

1

1

1

Other
Minimum pulse timer (2 pcs)

TPGAPC

2

2

2

Minimum pulse timer (2 pcs, second resolution)

TPSGAPC

1

1

1

Minimum pulse timer (2 pcs, minute resolution)

TPMGAPC

1

1

1

Pulse timer (8 pcs)

PTGAPC

2

2

2

Time delay off (8 pcs)

TOFGAPC

2

2

2

Time delay on (8 pcs)

TONGAPC

2

2

2

Set reset (8 pcs)

SRGAPC

2

2

2

Move (8 pcs)

MVGAPC

8

8

8

Generic control point (16 pcs)

SPCGGIO

2

2

2

Remote generic control points

SPCRGGIO

1

1

1

Local generic control points

SPCLGGIO

1

1

1

Generic up-down counters

UDFCNT

3

3

3

Analog value scaling function

SCA4GAPC

12

12

12

Integer value moving function

MVI4GAPC

2

2

2

1, 2, ... = number of included instances

() = optional

1) All directional protection functions can also be used in the non-directional mode

2) The instances of a protection function represent the number of identical protection function blocks available in the standard configuration

3) Only one can be ordered as an option at a time with OC or directional OC

4) Can be ordered as an option when OC is also chosen

5) Io selectable by parameter, Io measured by default

6) Can be ordered as an option when OC or directional OC is also chosen

7) One of the three can be ordered as an option when directional OC and directional EF are chosen: Admittance based EF, Wattmetric

based EF or Harmonics based EF

8) Uo calculated is always used

9) Uo calculated is always used with the first instance

10) UoB calculated is always used with the second instance

11) Voltage group B is always used with the third instance

12) Must be added with Application Configuration to be available in Signal Matrix and in the relay

13) Voltage group B is always used with the second instance

1MRS757807 B

Section 2

DNP3 data mappings

Remote Monitoring and Control REC615

17

Point List Manual

Содержание Relion REC615

Страница 1: ...Relion product family Grid Automation Remote Monitoring and Control REC615 DNP3 Point List Manual...

Страница 2: ......

Страница 3: ...Document ID 1MRS757807 Issued 2015 03 06 Revision B Product version 1 1 Copyright 2015 ABB All rights reserved...

Страница 4: ...s document is furnished under a license and may be used copied or disclosed only in accordance with the terms of such license Trademarks ABB and Relion are registered trademarks of the ABB Group All o...

Страница 5: ...ted and communicate data and information via a network interface which should be connected to a secure network It is the sole responsibility of the person or entity responsible for network administrat...

Страница 6: ...rning electrical equipment for use within specified voltage limits Low voltage directive 2006 95 EC This conformity is the result of tests conducted by ABB in accordance with the product standards EN...

Страница 7: ...nd failure protection 1 19 CTRL DCXSWI1 Disconnector control 1 19 CTRL DCXSWI2 Disconnector control 2 19 CTRL DCXSWI3 Disconnector control 3 20 CTRL DCXSWI4 Disconnector control 4 20 CTRL DCXSWI5 Disc...

Страница 8: ...7 LD0 DPHLPDOC2 Three phase directional overcurrent protection low stage 2 27 LD0 DPHHPDOC1 Three phase directional overcurrent protection high stage 1 27 LD0 EFLPTOC1 Non directional earth fault and...

Страница 9: ...oltage protection 2 32 LD0 PHPTOV3 Phase overvoltage protection 3 33 LD0 PSPTUV1 Positive sequence undervoltage protection 1 33 LD0 NSPTOV1 Negative sequence overvoltage protection 1 33 LD0 FRPFRQ1 Fr...

Страница 10: ...IO120 Physical I O 43 Automation functions 43 LD0 ATSABTC1 Automatic transfer switch 1 43 Binary outputs 43 System functions 44 LD0 DNPGGIO1 Parameter setting group control 1 44 LD0 LLN0 LPHD1 Reset i...

Страница 11: ...Disconnector control 4 52 CTRL DCXSWI5 Disconnector control 5 53 CTRL DCXSWI6 Disconnector control 6 53 CTRL DCXSWI7 Disconnector control 7 53 CTRL DCXSWI8 Disconnector control 8 53 CTRL ESSXSWI1 Ear...

Страница 12: ...signals 4 59 LD0 SCA4GAPC5 Multipurpose analog signals 5 60 LD0 SCA4GAPC6 Multipurpose analog signals 6 60 LD0 SCA4GAPC7 Multipurpose analog signals 7 60 LD0 SCA4GAPC8 Multipurpose analog signals 8 60...

Страница 13: ...manual addresses the communication system engineer or system integrator responsible for pre engineering and engineering for communication setup in a substation from an IED perspective The system engin...

Страница 14: ...ing guide Point list manual GUID 7414985D 2433 46E4 B77B CCE64F6FC8D0 V1 EN Figure 1 The intended use of documents during the product life cycle Product series and product specific manuals can be down...

Страница 15: ...ance leading to personal injury or death Therefore comply fully with all warning and caution notices 1 4 2 Document conventions A particular convention may not be used in this manual Abbreviations and...

Страница 16: ...Io 1 51N 1 1 Non directional earth fault protection high stage instance 1 EFHPTOC1 Io 1 51N 2 1 Non directional earth fault protection instantaneous stage instance 1 EFIPTOC1 Io 1 50N 51N 1 Directiona...

Страница 17: ...nstance 1 PSPTUV1 U1 1 47U 1 Negative sequence overvoltage protection instance 1 NSPTOV1 U2 1 47O 1 Frequency protection instance 1 FRPFRQ1 f f df dt 1 81 1 Frequency protection instance 2 FRPFRQ2 f f...

Страница 18: ...tance 3 ESSXSWI3 I O ES 3 I O ES 3 Earthing switch indication instance 4 ESSXSWI4 I O ES 4 I O ES 4 Earthing switch indication instance 5 ESSXSWI5 I O ES 5 I O ES 5 Earthing switch indication instance...

Страница 19: ...nce 2 TPGAPC2 TP 2 TP 2 Minimum pulse timer 2 pcs second resolution instance 1 TPSGAPC1 TPS 1 TPS 1 Minimum pulse timer 2 pcs minute resolution instance 1 TPMGAPC1 TPM 1 TPM 1 Pulse timer 8 pcs instan...

Страница 20: ...on instance 3 SCA4GAPC3 SCA4 3 SCA4 3 Analog value scaling function instance 4 SCA4GAPC4 SCA4 4 SCA4 4 Analog value scaling function instance 5 SCA4GAPC5 SCA4 5 SCA4 5 Analog value scaling function in...

Страница 21: ...2 2 Supported functions in REC615 Table 2 Supported functions Function IEC 61850 A B C CE01 CE02 CE03 Protection1 2 Three phase non directional overcurrent protection low stage PHLPTOC 1 3 1 3 1 3 Th...

Страница 22: ...ip TRPPTRC 2 2 2 Multi purpose protection MAPGAPC 6 6 6 Load shedding and restoration LSHDPFRQ 1 1 1 Fault locator SCEFRFLO 1 1 1 Power quality Current total demand distortion CMHAI 1 1 1 Voltage tota...

Страница 23: ...of included instances optional 1 All directional protection functions can also be used in the non directional mode 2 The instances of a protection function represent the number of identical protection...

Страница 24: ...ut states 2 3 1 System functions 2 3 1 1 CTRL LLN0 Local remote state also present in DNP IIN bits Table 4 CTRL LLN0 Local remote state also present in DNP IIN bits IEC 61850 name SA name Description...

Страница 25: ...name SA name Description Values CTRL DCCILO1 EnaCls stVal ENA_CLOSE Close enabled 1 Enabled EnaOpn stVal ENA_OPEN Open enabled 1 Enabled ItlByPss stVal ITL_BYPASS Interlocking bypass 1 Bypassed CTRL...

Страница 26: ...TRL DCXSWI4 Disconnector control 4 Table 11 CTRL DCXSWI4 Disconnector control 4 IEC 61850 name SA name Description Values CTRL DCCILO4 EnaCls stVal ENA_CLOSE Close enabled 1 Enabled EnaOpn stVal ENA_O...

Страница 27: ...bypass 1 Bypassed CTRL DCCSWI6 Pos stSeld SELECTED CB selected 1 Selected CTRL DCXSWI6 BlkCls stVal BLK_CLOSE Close blocked 1 Blocked BlkOpn stVal BLK_OPEN Open blocked 1 Blocked 2 3 2 8 CTRL DCXSWI7...

Страница 28: ...l CB_LIFE_ALM CB lifetime alarm 1 Alarm ClsAlm stVal TRV_T_CL_ALM Cls travel time alarm 1 Alarm LonTmAlm stVal MON_ALM CB inactive alarm 1 Alarm OpnAlm stVal TRV_T_OP_ALM Cls travel time alarm 1 Alarm...

Страница 29: ...IEC 61850 name SA name Description Values LD0 TCSSCBR2 CirAlm stVal ALARM Supervision alarm 1 Alarm 2 3 3 5 LD0 MDSOPT1 Generic operation time supervision 1 Table 20 LD0 MDSOPT1 Generic operation tim...

Страница 30: ...nce 1 Low voltage VDeaPhsA stVal U_A_AB_DEAD Low phsA or phsAB voltage 1 Low voltage VDeaPhsB stVal U_B_BC_DEAD Low phsB or phsBC voltage 1 Low voltage VDeaPhsC stVal U_C_CA_DEAD Low phsC or phsCA vol...

Страница 31: ...VMMXU2 HiAlm stVal HIGH_ALARM High alarm 1 Alarm HiWrn stVal HIGH_WARN High warning 1 Warning LoAlm stVal LOW_ALARM Low alarm 1 Alarm LoWrn stVal LOW_WARN Low warning 1 Warning 2 3 5 Power quality fun...

Страница 32: ...B1 VarStr stVal Event start 1 Start HiPctVUnb stVal Unbalance exceeds limit 1 Exceeds 2 3 6 Protection functions 2 3 6 1 LD0 PHLPTOC1 Phase overcurrent protection low stage 1 Table 31 LD0 PHLPTOC1 Pha...

Страница 33: ...perate Str general START Start 1 Start 2 3 6 5 LD0 DPHLPDOC2 Three phase directional overcurrent protection low stage 2 Table 35 LD0 DPHLPDOC2 Three phase directional overcurrent protection low stage...

Страница 34: ...p general OPERATE Operate 1 Operate Str general START Start 1 Start 2 3 6 9 LD0 EFIPTOC1 Non directional earth fault and sensitive earth fault protection instantaneous stage 1 Table 39 LD0 EFIPTOC1 No...

Страница 35: ...43 LD0 INTRPTEF1 Intermittent earth fault protection 1 IEC 61850 name SA name Description Values LD0 INTRPTEF1 Str general START General Start 1 Start Op general OPERATE General Operate 1 Operate 2 3...

Страница 36: ...Wattmetric based earth fault protection 2 IEC 61850 name SA name Description Values LD0 WPDSE2 Str general START Stage 2 start 1 Start Op general OPERATE Stage 2 operate 1 Operate 2 3 6 19 LD0 WPWDE3...

Страница 37: ...3 LD0 PDNSPTOC1 Phase discontinuity protection 1 IEC 61850 name SA name Description Values LD0 PDNSPTOC1 Op general OPERATE Stage operate 1 Operate Str general START Stage start 1 Start 2 3 6 24 LD0 R...

Страница 38: ...PTUV3 Phase undervoltage protection 3 IEC 61850 name SA name Description Values LD0 PHPTUV3 Op general OPERATE Stage operate 1 Operate Str general START Stage start 1 Start 2 3 6 29 LD0 PHPTOV1 Phase...

Страница 39: ...V1 Negative sequence overvoltage protection 1 Table 63 LD0 NSPTOV1 Negative sequence overvoltage protection 1 IEC 61850 name SA name Description Values LD0 NSPTOV1 Op general OPERATE Stage operate 1 O...

Страница 40: ...ame Description Values LD0 T1PTTR1 AlmThm general ALARM Thermal alarm 1 Alarm Op general OPERATE General operate 1 Operate Str general START General start 1 Start 2 3 6 37 LD0 INRPHAR1 Three phase inr...

Страница 41: ...ls 1 Table 71 LD0 LEDPTRC1 Global protection signals 1 IEC 61850 name SA name Description Values LD0 LEDPTRC1 Global protection signals Op general General Operate 1 Operate Op phsA phsA Operate 1 Oper...

Страница 42: ...Val Reclaim time started 1 Started ProCrd stVal Protection coordination 1 In progress Op general CLOSE_CB Operate close XCBR 1 Close CB OpOpn general OPEN_CB Operate open XCBR 1 Open CB UnsCBCls stVal...

Страница 43: ...77 LD0 MAPGAPC3 Multipurpose analog protection function 3 IEC 61850 name SA name Description Values LD0 MAPGAPC3 Op general OPERATE Stage operate 1 Operate Str general START Stage start 1 Start 2 3 8...

Страница 44: ...Off On Q4 stVal Input 4 signal 0 1 Off On Q5 stVal Input 5 signal 0 1 Off On Q6 stVal Input 6 signal 0 1 Off On Q7 stVal Input 7 signal 0 1 Off On Q8 stVal Input 8 signal 0 1 Off On 2 3 8 8 LD0 MVGAPC...

Страница 45: ...t 1 signal 0 1 Off On Q2 stVal Input 2 signal 0 1 Off On Q3 stVal Input 3 signal 0 1 Off On Q4 stVal Input 4 signal 0 1 Off On Q5 stVal Input 5 signal 0 1 Off On Q6 stVal Input 6 signal 0 1 Off On Q7...

Страница 46: ...t 1 signal 0 1 Off On Q2 stVal Input 2 signal 0 1 Off On Q3 stVal Input 3 signal 0 1 Off On Q4 stVal Input 4 signal 0 1 Off On Q5 stVal Input 5 signal 0 1 Off On Q6 stVal Input 6 signal 0 1 Off On Q7...

Страница 47: ...te 0 1 Off On SPCS15 stVal Output 15 state 0 1 Off On SPCS16 stVal Output 16 state 0 1 Off On 2 3 8 16 LD0 SPCRGGIO1 Multipurpose binary output status 1 Table 90 LD0 SPCRGGIO1 Multipurpose binary outp...

Страница 48: ...ON OFF SPCSO6 stVal X100 Output 6 1 0 ON OFF 2 3 9 2 LD0 XGGIO110 Physical I O Table 92 LD0 XGGIO110 Physical I O IEC 61850 name SA name Description Values LD0 XGGIO110 Ind1 stVal X110 Input 1 1 0 ON...

Страница 49: ...ocked alarm 1 Alarm PrgAuto stVal INPRO ATS in progress 1 In progress 2 4 Binary outputs Table 95 Explanations of the binary output table columns Column name Description IEC 61850 name Original IED da...

Страница 50: ...eset device 1 IEC 61850 name SA name Description Type LD0 LLN0 LEDRs1 Oper ctlVal Reset indications and LEDs On LEDRs2 Oper ctlVal Reset alarm LEDs On LD0 LPHD1 RsDev Oper ctlVal Reset device On 2 4 2...

Страница 51: ...CSWI4 Pos Oper ctlVal Disconnector control On Off 2 4 2 6 CTRL DCXSWI5 Disconnector control 5 Table 103 CTRL DCXSWI5 Disconnector control 5 IEC 61850 name SA name Description Type CTRL DCCSWI5 Pos Ope...

Страница 52: ...RST_TRV_T Reset travel time alarm On 2 4 3 2 LD0 SSCBR2 Reset signals of CB condition monitoring 2 Table 108 LD0 SSCBR2 Reset signals of CB condition monitoring 2 IEC 61850 name SA name Description T...

Страница 53: ...op 3 On Rs4 Oper ctlVal Reset flip flop 4 On Rs5 Oper ctlVal Reset flip flop 5 On Rs6 Oper ctlVal Reset flip flop 6 On Rs7 Oper ctlVal Reset flip flop 7 On Rs8 Oper ctlVal Reset flip flop 8 On 2 4 6 2...

Страница 54: ...ntrol On Off SPCSO11 Oper ctlVal Output 11 control On Off SPCSO12 Oper ctlVal Output 12 control On Off SPCSO13 Oper ctlVal Output 13 control On Off SPCSO14 Oper ctlVal Output 14 control On Off SPCSO15...

Страница 55: ...ritten with both values 1 and 0 The setting mode toggled for local operation corresponds to persistent for remote operation Table 115 LD0 SPCRGGIO1 Multipurpose binary outputs 1 IEC 61850 name SA name...

Страница 56: ...ected as default Default R means ratio scaling See the DNP3 communication protocol manual for details Arg 1 2 3 4 Scaling argument values as default When ratio scaling is selected the four values corr...

Страница 57: ...rm R 0 3 0 3 ISCSO9 stVal LED 9 state 0 1 3 Off Ok Alarm R 0 3 0 3 ISCSO10 stVal LED 10 state 0 1 3 Off Ok Alarm R 0 3 0 3 ISCSO11 stVal LED 11 state 0 1 3 Off Ok Alarm R 0 3 0 3 2 5 1 4 LD0 LPHD1 Sys...

Страница 58: ...onnector control 2 Table 123 CTRL DCXSWI2 Disconnector control 2 IEC 61850 name SA name Description Values S Arg 1 2 3 4 CTRL DCXSWI2 Pos stVal POSITION Intermediate 0 Off 1 On 2 Bad 3 0 3 R 0 3 0 3 2...

Страница 59: ...connector control 7 IEC 61850 name SA name Description Values S Arg 1 2 3 4 CTRL DCXSWI7 Pos stVal POSITION Intermediate 0 Off 1 On 2 Bad 3 0 3 R 0 3 0 3 2 5 2 9 CTRL DCXSWI8 Disconnector control 8 Ta...

Страница 60: ...XSWI4 Earthing switch indication 4 IEC 61850 name SA name Description Values S Arg 1 2 3 4 CTRL ESSXSWI4 Pos stVal POSITION Intermediate 0 Off 1 On 2 Bad 3 0 3 R 0 3 0 3 2 5 2 14 CTRL ESSXSWI5 Earthin...

Страница 61: ...50 name SA name Description Values S Arg 1 2 3 4 LD0 CMMXU1 Phase to ground current A phsA instCVal mag I_INST_A phsA magnitude 0 00 40 0 xIn R 0 40 0 4000 A phsB instCVal mag I_INST_B phsB magnitude...

Страница 62: ...nitude 0 00 4 00 xUn R 0 4 0 400 phsBC cVal mag U_DB_BC phsBC magnitude 0 00 4 00 xUn R 0 4 0 400 phsCA cVal mag U_DB_CA phsCA magnitude 0 00 4 00 xUn R 0 4 0 400 2 5 3 5 LD0 VMMXU2 Voltage measuremen...

Страница 63: ...2 3 4 LD0 VSMSQI2 Sequence of voltages SeqV c1 cVal mag I1_DB Positive magnitude 0 00 4 00 xUn R 0 4 0 400 SeqV c2 cVal mag I2_DB Negative magnitude 0 00 4 00 xUn R 0 4 0 400 SeqV c3 cVal mag I3_DB Z...

Страница 64: ...5 4 Protection functions 2 5 4 1 LD0 T1PTTR1 Thermal protection values 1 Table 148 LD0 T1PTTR1 Thermal protection values 1 IEC 61850 name SA name Description Values S Arg 1 2 3 4 LD0 T1PTTR1 Tmp mag...

Страница 65: ...t4 mag AO4_VALUE Analog value 4 10000 10000 R 1E4 1E4 1E4 1E4 2 5 6 3 LD0 SCA4GAPC3 Multipurpose analog signals 3 Table 153 LD0 SCA4GAPC3 Multipurpose analog signals 3 IEC 61850 name SA name Descripti...

Страница 66: ...ALUE Analog value 4 10000 10000 R 1E4 1E4 1E4 1E4 2 5 6 7 LD0 SCA4GAPC7 Multipurpose analog signals 7 Table 157 LD0 SCA4GAPC7 Multipurpose analog signals 7 IEC 61850 name SA name Description Values S...

Страница 67: ...E Analog value 4 10000 10000 R 1E4 1E4 1E4 1E4 2 5 6 11 LD0 SCA4GAPC11 Multipurpose analog signals 11 Table 161 LD0 SCA4GAPC11 Multipurpose analog signals 11 IEC 61850 name SA name Description Values...

Страница 68: ...UT4 Interger value 4 2147483647 R max max max max 2 5 6 14 LD0 MVI4GAPC2 Integer value moving function 2 Table 164 LD0 MVI4GAPC2 Integer value moving function 2 IEC 61850 name SA name Description Valu...

Страница 69: ...complete list is described in the attached table For static non change event object requests request qualifier codes 07 and 08 limited quantity and 17 and 28 index are supported Static object request...

Страница 70: ...is accepted but ignored Never Always Sometimes Configurable Pulse on Never Always Sometimes Configurable Pulse off Never Always Sometimes Configurable Latch on Never Always Sometimes Configurable Latc...

Страница 71: ...file mode Yes No Custom status code strings Yes No Permissions field Yes No File events assigned to class Yes No File events send immediately Yes No Multiple blocks in a fragment Yes No Max number of...

Страница 72: ...28 index 2 21 Binary input change with time 1 read 06 no range or all 07 08 limited qty 129 response 130 unsol resp 17 28 index 2 3 Binary input change with relative time 1 read 06 no range or all 07...

Страница 73: ...2 2 16 bit analog change event without time 1 read 06 no range or all 07 08 limited qty 129 response 130 unsol resp 17 28 index 32 3 32 bit analog change event with time 1 read 06 no range or all 07 0...

Страница 74: ...ect function code only 23 delay meas No object function code only 24 record current time 1 A default variation refers to the variation responded when variation 0 is requested and or in class 0 1 2 or...

Страница 75: ...e ownership of the protocol and assumes responsibility for its evolution EF Earth fault EMC Electromagnetic compatibility HMI Human machine interface IEC International Electrotechnical Commission IEC...

Страница 76: ...70...

Страница 77: ...71...

Страница 78: ......

Страница 79: ......

Страница 80: ...BB Oy Medium Voltage Products Distribution Automation P O Box 699 FI 65101 VAASA Finland Phone 358 10 22 11 Fax 358 10 22 41094 www abb com substationautomation 1MRS757807 B Copyright 2015 ABB All rig...

Отзывы: