www.abb.com/jokabsafety 23
2TLC172213M0201, rev. B
8
Troubleshooting
Operating the door when electrical supply is disconnected
The door can be opened/closed manually by the crank for the drive unit. Place the crank in the tap in the bottom of
the motor. Disengage the brake by pulling the brake handle and turn the crank at the same time.
Warning!
When the crank is placed in the tap in the bottom of the motor the electrical supply to the motor is
automatically switched off. Electrical supply to the door should always be switched off via the line circuit breaker
before the door is operated by the crank.
Error indication Eden sensors
The LED has the following states:
LED
Indication
Description
LED on Eden
Green
Eva within range, safety circuit closed; door closed.
Green-Red (flashing)
Eva within range; the door is closed but the signal is not OK.
Red
Eva out of range, safety circuit open; door open.