2TLC172213M0201, rev. B
18 www.abb.com/jokabsafety
Step 9 – Electrical cabinet
Make the connections as follows. See chapter 11 ”Connection examples”.
Connection block
Equipment
L1, L2, L3
Electrical supply
N, PE
Neutral, Earth
1-4 (X1)
Supply for motor
3-4 (X3)
Connection of external button/signal for controlling door movement upwards
5-6 (X3)
Connection of external button/signal for controlling door movement downwards
7-8 (X3)
Connection of external button/signal for stopping the door
20 (X3)
Reset button
21 (X3)
Reset button
22 (X3)
Lamp in reset button
23-27 (X3)
Eden 1. Safety switch for supervision of closed position of the door.
28-32 (X3)
Eden 2. Safety switch for supervision of closed position of the door.
33-36 (X3)
Connection of contact strip
37-44 (X3)
Option: Focus II Receiver M12
45-48 (X3)
Option: Focus II Transmitter M12
50-51
Safety output; to be connected to the machine
52-53
Safety output; to be connected to the machine