Operation Manual / Power2 650-M / Low-pressure stage
9 Disassembly and assembly / 9.14 Installing the wall insert
© Copyright 2022 ABB. All rights reserved.
HZTL4065_EN
Rev.E
March 2022
Fig. 45: Installing the wall insert 2
Part number
Tightening torque
72002
M16x334
50 Nm
Table 45: Tightening torque (72002)
1. Remove plate (90032), screw (90656), nut (90432) and plates (90031).
2. Remove the bracket (90030).
3. Detach speed measurement cable from provisional holder and insert cable con-
nector (86515).
4. Fit four studs (72002) in the upper area. Observe tightening torque.
Page
86
/