background image

 

26  CI/EDP300-EN Rev. C | 

PositionMaster EDP300 

 

 

6.6.3

 

Setting the mechanical binary feedback with 24 V 
microswitches 

1.

Loosen the screws for the housing cover and remove it. 

2.

Select "Manual Adjustment" operating mode and move the 
valve by hand into the desired switching position for 
contact 1. 

3.

Set maximum contact (1, lower washer). 

 

Fasten the upper washer with the special adjustment 
retainer and rotate the lower washer manually. 

4.

Select "Manual Adjustment" operating mode and move the 
valve by hand into the desired switching position for 
contact 2. 

5.  Set minimum contact (2, upper washer); 
 

Fasten the lower washer with the special adjustment 
retainer and rotate the upper washer manually. 

6.

Connect the microswitch. 

7.

Attach the housing cover and screw it on to the housing. 

8.

Tighten the screws so that they are hand-tight. 

 

 

 

6.7

 

Pneumatic connections 

 

NOTICE

 

The positioner must only be supplied with instrument air that 
is free of oil, water, and dust (in gas configuration with dried 
natural gas). 
The purity and oil content must meet the requirements of 
Class 3 according to DIN/ISO 8573-1. 

 

NOTICE

 

Damage to components! 

Contamination on the air pipe and positioner can damage 
components. 
Dust, splinters, and any other particles of dirt must be blown 
off the pipe before it is connected. 

 

NOTICE

 

Damage to components! 

Pressure above 10 bar (145 psi) can damage the positioner 
or actuator. 
Provisions must be made (e.g., use of a pressure regulator) 
to ensure that the pressure does not rise above 10 bar 
(145 psi), even in the event of a fault. 

 

6.7.1

 

Information on double acting actuators with spring-
return mechanism 

On double-acting actuators with spring-return mechanism, a 
pressure that significantly exceeds the supply air pressure 
value can be generated during operation by the springs in the 
chamber opposite the springs. 
This may damage the positioner or adversely affect control of 
the actuator. 
To eliminate the possibility of this occurring, it is 
recommended 
to install a pressure compensation valve between the 
springless chamber and the supply air for these types of 
applications. It enables the increased pressure to be 
transferred back to the air inlet line. 
The opening pressure of the check valve should be < 250 
mbar (< 3.6 psi). 
 

Содержание PositionMaster EDP300

Страница 1: ...Commissioning Instruction CI EDP300 EN Rev C PositionMaster EDP300 Digital Positioner...

Страница 2: ...Additional documentation on PositionMaster EDP300 is available to download free of charge at www abb com positioners Alternatively simply scan this code Manufacturer ABB Automation Products GmbH Indus...

Страница 3: ...Electrical connection to the EDP300 remote sensor 19 6 4 3 Electrical data for inputs and outputs 19 6 4 4 Connection on the device 21 6 4 5 Connection to device EDP300 Control Unit with EDP300 Remot...

Страница 4: ...uctions are structured as follows DANGER The signal word DANGER indicates an imminent danger Failure to observe this information will result in death or severe injury WARNING The signal word WARNING i...

Страница 5: ...only by persons whose training has included instructions on different types of protection and installation techniques concerned rules and regulations as well as general principles of zoning The perso...

Страница 6: ...or fully depressurized ensure that there is no possibility of a hazardous atmosphere getting into the pneumatic system or that any hazardous atmosphere is removed prior to compression by taking suitab...

Страница 7: ...ith proximity switch1 Terminals Limit 1 51 52 Limit 2 41 42 Temperature class T1 T4 Temperature class T6 In accordance with type examination certificate PTB 00 ATEX 2049X 1 No IECEx approval 2 5 2 Typ...

Страница 8: ...perator must strictly observe the applicable national regulations with regard to installation function tests repairs and maintenance of electrical devices e g NEC CEC NOTICE Observe the device s appli...

Страница 9: ...EDP300 fully several times 3 4 Temperature data NOTICE Legibility of the display is guaranteed at an ambient temperature of 20 70 C At 20 C and lower legibility can become limited Legibility can be c...

Страница 10: ...t UAI Terminals 21 22 Temperature class T1 T4 Temperature class T6 Ui 30 V Ui 28 V Ii 320 mA Ii 320 mA Pi 1 W Pi 0 8 W Ci 11 3 nF Li 150 H Module for digital feedback SW1 SW2 Terminals SW 1 41 42 SW 2...

Страница 11: ...ed are examples The device identification plates affixed to the device can differ from this representation Change from one to two columns 5 Transport 5 1 Inspection Check the devices immediately after...

Страница 12: ...is being operated on a cylinder for reasons associated with linearity you should run the Auto Adjust function for rotary actuators see chapter Start Auto Adjust function on page 31 A EDP300 control un...

Страница 13: ...e of rotary actuators The usable span is 90 which must be entirely within the measuring range but does not necessarily need to run symmetrically to the longitudinal axis NOTICE During installation mak...

Страница 14: ...used for the mount bracket 5 Secure the mount bracket 1 with screws 2 and washers 3 using the relevant tap holes on the positioner housing Tighten the screws as evenly as possible to ensure subsequen...

Страница 15: ...commended range for linear actuators 30 30 minimum range 25 NOTICE After mounting check whether the positioner is operating within the sensor range Position of actuator bolt The actuator bolt for movi...

Страница 16: ...n actuators For mounting on part turn actuators in accordance with VDI VDE 3845 the following attachment kit is available Fig 15 Components of attachment kit Adapter 1 with spring 5 Four screws M6 4 f...

Страница 17: ...t be taken into account when determining the adapter position on the feedback shaft 1 For this purpose the feedback shaft can be adjusted manually so that the adapter 3 can be attached in the correct...

Страница 18: ...res for them Change from two to one column 6 4 1 Electrical connection to positioner EDP300 Control Unit Fig 19 Electrical connection EDP300 A Basic device B Options C EDP Remote Sensor Connection rem...

Страница 19: ...lly explosive atmospheres note the additional data in chapter Use in potentially explosive atmospheres according to ATEX and IECEx on page 5 and in chapter Use in potentially explosive atmospheres in...

Страница 20: ...n function1 When the 24 V DC signal is interrupted the I P module executes the respective safety function depending on the mechanical construction The positioner output 1 is depressurized and the valv...

Страница 21: ...25 1 5 mm2 AWG 23 AWG 17 Flexible with wire end sleeve with plastic sleeve 0 14 0 75 mm2 AWG 26 AWG 20 Multi wire connection capacity two wire with the same cross section Rigid flexible wires 0 14 0...

Страница 22: ...rol Unit housing 1 and remote position sensor EDP300 Remote Sensor housing 2 while following the instructions below The EDP300 Remote Sensor and the EDP300 Control Unit are adjusted to each other Ensu...

Страница 23: ...of 10 m 33 ft must be used for connection purposes Route the cable into the terminal compartment through the EMC cable glands Ensure that the shielding is secured correctly in the EMC cable glands Con...

Страница 24: ...with the 24 V DC signal terminal 85 86 interrupted 6 5 1 Installing the mechanical position indicator 1 Loosen the screws for the housing cover and remove it 2 Attach the extension shaft to the feedba...

Страница 25: ...the desired position 3 Attach the housing cover and screw it onto the housing Tighten the screws so that they are hand tight 4 Attach the symbol label to mark the minimum and maximum valve positions o...

Страница 26: ...ntent must meet the requirements of Class 3 according to DIN ISO 8573 1 NOTICE Damage to components Contamination on the air pipe and positioner can damage components Dust splinters and any other part...

Страница 27: ...imensions of 12 x 1 75 mm The level of supply air pressure required to apply the actuating force must be adjusted in line with the output pressure in the actuator The working range for the positioner...

Страница 28: ...the end positions and Auto Adjust is then carried out With large actuators it can occur that the time for automatic adjustment is significantly than in smaller actuators 7 3 1 Moving to end positions...

Страница 29: ...s which enable the device to be operated with the housing cover open 8 2 1 Menu navigation 2 5 Menu 3 4 5 Exit Select Fig 27 LCD display 1 Operating buttons for menu navigation 2 Menu name display 3 M...

Страница 30: ...not be changed on this level Operating modes menu In the operating modes menu the Auto Adjust function can be started for commissioning purposes You can also change the operating modes and switch to t...

Страница 31: ...NOTICE Auto Adjust does not always result in optimum control conditions When Auto Adjust is started via shortcut keys the position of the valve is determined automatically 9 Maintenance The positione...

Страница 32: ...rable zone 0 100 Configurable dead zone 0 1 10 Resolution AD conversion 16 000 steps Sampling frequency 20 ms Ambient temperature effect 0 5 for each 10 K Influence of vibration 1 to 10 g and 80 Hz 1...

Страница 33: ...y Address Contact person Telephone Fax E Mail Device details Typ Serial no Reason for the return description of the defect Was this device used in conjunction with substances which pose a threat or ri...

Страница 34: ...34 CI EDP300 EN Rev C PositionMaster EDP300 12 2 Control Drawing 901305...

Страница 35: ...PositionMaster EDP300 CI EDP300 EN Rev C 35...

Страница 36: ...36 CI EDP300 EN Rev C PositionMaster EDP300...

Страница 37: ...PositionMaster EDP300 CI EDP300 EN Rev C 37...

Страница 38: ...38 CI EDP300 EN Rev C PositionMaster EDP300...

Страница 39: ...PositionMaster EDP300 CI EDP300 EN Rev C 39...

Страница 40: ...positioners Note We reserve the right to make technical changes or modify the contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB do...

Отзывы: