PositionMaster EDP300
DIGITAL POSITIONER | CI/EDP300-EN REV. D
11
Operation with flammable gases
Observe the following points when operating a device with
flammable gases:
• The device must be used in accordance with the
specifications in the relevant certificate.
• Only the design with the IS ‘Intrinsic Safety’ type of
protection may be operated with natural gas. The
pneumatic outputs must be vented in non-hazardous
areas.
• During operation with flammable gases, the cover cap for
the air outlets must be removed and the air outlets tubed
separately. Both pipes must not be joined in one pipe.
• The maximum ambient temperature must not up-scale
60 °C (140 °F).
See also
Control Drawing 901305
on page 44.
Operation in areas with combustible dust
Observe the following points when operating a device with
combustible dust:
• To prevent loss of type of protection, the housing must
not be opened.
• Only use cable glands which are approved for the type of
protection and correspond to IP rating
≥
IP 6X.
• Danger due to propagating brush discharge must be
avoided.
Operation in temperature class T6
During operation in temperature class T6, when the equipment
is partially or fully depressurized, ensure that there is no
possibility of an explosive atmosphere getting into the
pneumatic system or that any explosive atmosphere is removed
prior to compression by taking suitable action.
When commissioning in temperature class T6, flush the
pneumatic system by applying 1.4 (±0.1) bar until all traces of any
explosive mixture have been removed, yet for at least 5 minutes.
Ventilate and evacuate the EDP300 fully several times.
Temperature data
Note
Legibility of the display is guaranteed at an ambient
temperature of
−
20 to 70 °C. At 20 °C and lower, legibility can
become limited. Legibility can be compensated by adjusting
contrast. Contrast adjustment can be made manually directly on
the device.
The display can fail at temperatures below
−
20 °C. Moreover,
functioning of the device is guaranteed up to
−
40 °C.
FM
Temperature class
Ambient temperature T
amb
T1 to T4
−
40 °C to 85 °C
T6
−
40 °C to 40 °C
CSA
Temperature class
Ambient temperature T
amb
T4
−
40 °C to 85 °C
T6
−
40 °C to 40 °C
Содержание PositionMaster EDP300
Страница 44: ...44 PositionMaster EDP300 DIGITAL POSITIONER CI EDP300 EN REV D 13 Appendix Control Drawing 901305...
Страница 45: ...PositionMaster EDP300 DIGITAL POSITIONER CI EDP300 EN REV D 45...
Страница 46: ...46 PositionMaster EDP300 DIGITAL POSITIONER CI EDP300 EN REV D 13 Appendix Control Drawing 901305...
Страница 47: ...PositionMaster EDP300 DIGITAL POSITIONER CI EDP300 EN REV D 47...
Страница 48: ...48 PositionMaster EDP300 DIGITAL POSITIONER CI EDP300 EN REV D 13 Appendix Control Drawing 901305...
Страница 49: ...PositionMaster EDP300 DIGITAL POSITIONER CI EDP300 EN REV D 49...
Страница 51: ...PositionMaster EDP300 DIGITAL POSITIONER CI EDP300 EN REV D 51 Note...