Running LoadIdentify
To start the load identification service routine you must have an active program in
manual mode. Also the tool and payload that you want to identify must be defined
and active in
Jog
.
Tip
Always run load identification with cold motors (no warm-up).
1 On the start screen, tap
Operate
, and then select
Service Routines
from the
menu.
2 Tap LoadIdentify.
3 Press the three-position enabling device.
4 In the
Control Panel
tap
Play
. You can also press the
START
hard button
on the FlexPendant.
The
Load Identification
operator message window is displayed.
5 Tap
OK
to confirm that current path will be cleared and that the program
pointer will be lost.
6 In the operator message window, tap
Tool
or
PayLoad
.
7 Tap
OK
to confirm that the correct tool or payload is active in the jogging
menu and that the tool or payload is correctly mounted.
Note
If it is not correct, release the three-position enabling device and select
the correct tool/payload in the
Jogging
menu. Then return to LoadIdentify,
press the three-position enabling device, and press Start. Tap
Retry
and
confirm that the new tool/payload is correct.
8 When identifying tool loads, confirm that the tool is active.
When identifying payloads, confirm that the payload’s tool is active and
calibrated.
9 When identifying payloads with stationary TCP, confirm that the correct work
object is active and (preferably) calibrated. If it is correct, tap
OK
to confirm.
10 Select identification method. If you select the method where the mass is
assumed to be known, remember that the tool/payload that you use must
have the correct mass defined. Tap
OK
to confirm.
11 Select the configuration angle. The optimum is +90 or -90 degrees. If this is
impossible, tap
Other
and set the angle. The minimum is +30 or -30 degrees.
12 If the robot is not in a correct position for load identification, you will be asked
to jog one or more axes roughly to a specified position. When you have done
this tap
OK
to confirm.
Continues on next page
Operating manual - OmniCore
169
3HAC065036-001 Revision: E
© Copyright 20192020 ABB. All rights reserved.
6 Programming and testing
6.10.6 Load identification service routine
Continued
Содержание OmniCore C30
Страница 1: ...ROBOTICS Operating manual OmniCore ...
Страница 2: ...Trace back information Workspace RW 7 1 version a5 Checked in 2020 10 25 Skribenta version 5 3 075 ...
Страница 8: ...This page is intentionally left blank ...
Страница 22: ...This page is intentionally left blank ...
Страница 54: ...This page is intentionally left blank ...
Страница 60: ...This page is intentionally left blank ...
Страница 64: ...This page is intentionally left blank ...
Страница 208: ...This page is intentionally left blank ...
Страница 234: ......
Страница 235: ......