You can use the ratio between
T
stator_rise
and the thermal model
temperature rise, when estimating
how much the Thermal supervi-
sion sensitivity ratio should be
changed.
If T
stator_rise
is larger than the thermal model temper-
ature rise, then increase the thermal supervision
sensitivity ratio.
If T
stator_rise
is smaller than the thermal model tem-
perature rise, then decrease the thermal supervision
sensitivity ratio.
3
If T
stator_rise
+
Max temperature robot
> 130°C (max
allowed is 140°C, hot motor warnings will appear
at 130°C) consider actions to reduce the temperat-
ure, for example improving the cooling, reducing
the average torque, or choosing a larger motor unit
or gear unit.
4
Related information
Technical reference manual - System parameters
Application manual - TuneMaster
76
Product manual - Motor Units and Gear Units
3HAC040148-001 Revision: K
© Copyright 2011 -2018 ABB. All rights reserved.
6 Tuning the thermal supervision
Continued