- 38 -
01
1C5
5 - Troubleshooting
V
erification of ground leakage
In the presence of anomalies or report of ground fault, there may be a ground leakage from the
photovoltaic module.
To check this, measure the voltage between the positive pole and ground and between the negative
pole and ground using a voltmeter.
B
ehavior of a system without leakage
'XHWRWKHFDSDFLWLYHHIIHFWRIWKHSKRWRYROWDLFPRGXOHGXULQJWKH¿UVWPRPHQWVWKDWWKH
voltmeter is connected between one of the two poles and ground, it will measure a voltage of
about Voc/2, which will tend to stabilize to around 0V if there is no ground leakage, as shown
in the graph below:
The internal resistance of
the voltmeter tends to zero
the voltage present on the
PV generator due to the
capacitive effect
How to make the measurement:
f
Содержание MICRO-0.25-I-OUTD-US-208/240