2TLC172315M0201, rev. K
23
www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
Specifically for North American market (UL)
Encapsulation
Type 1
Intended usage
Applications as NFPA 79
Connecting cables
Cables to comply with CYJC/7, with a conductor area of min 0.2 mm
2
.
Power source
Power source (Limited voltage) to comply with:
Available voltage potential for secondary circuit may not exceed 30 VDC.
All external connecting cables are to be protected against fire and damage
to insulation due to overloads or short circuits according to following table,
based on conductor area.
Suitable for use in circuits with low voltage/low power only.
Low voltage/low power source must satisfy one of following requirements:
a)
To be fitted with an insulator that limits the maximum voltage potential
of open circuit to +24 VDC and current to max 8 A measured after 1 minute
in operation.
or
b)
Fitted with a suitable insulator and a fuse that complies with UL248
requirements. Fuse to have a rated current of max 3 A and be fitted in the
power unit (+24 VDC) such that the available current is limited.
Conductor area
Max current limit for overload protection:
AWG (mm
2
) Amps
24
(0.20) 2
22
(0.32)
3
20
(0.52) 5
18
(0.82) 7
Certification/Harmonized Standards
Conforms to
Machinery Directive 2006/42/EU
EN ISO 13849-1:2015, EN 62061:2005/A2:2015 EN 60204-1:2006/A1:2009,
IEC/EN 60664-1:2007/A1:2011, EN 61000-6-2:2005, EN 61000-6-
4:2007/A1:2011, EN 60947-5-3:2013, EN ISO 14119:2013
IEC/EN 61508-
1…7:2010
SIL3, PFH
D
: 4.50*10
-9
EN 62061:2005/A2:2015
SIL3, PFH
D
: 4.50*10
-9
EN ISO 13849-1:2015
Performance level: PLe, Category 4, PFH
D
: 4.50*10
-9
Certification
TÜV Süd, cULus
Warning The safety-related values are based on interlocking device Eden and do not
include the
locking function.
Important
! For further details about the integrated interlocking device, please see user instructions for Eden,
available at www.abb.com/jokabsafety.