2TLC172315M0201, rev K
18
www.abb.com/jokabsafety
Monday, May 07, 2018 10:51:13 AM
6 Operation
Locking:
1. Close the door.
2. Locking as PLC program (e.g. via signal from push button).
Unlocking:
1. Unlocking as PLC program (e.g. via signal from push button, or automatically when the machine/process
cycle is ended as it is supposed to).
2. Open the door.
LED indication
LED
Indication
Description
LED on Magne
(Magne 4)
Green
Eva close, safety circuit closed (door closed)
Green
–Red (blinking)
Eva close, safety circuit broken earlier (door closed)
Green
–Red (rapid
blinking)
Eva is within 2 mm of max sensory distance (door closed)
Red
Eva remote, safety circuit broken (door open)
LED on Magne
(Magne 3 and 4)
Blue (rapid blinking)
Overcurrent signaled on attempted locking.
Blue (slow blinking)
Lock signal but Magne not detecting the anchor plate.
Blue
Magne is locked.