1.9 Customer connections
Introduction to customer connections
The cables for customer connection are integrated in the robot and the connectors
are placed at the outer arm and base. There are two connectors C1/C2 at the outer
arm. Corresponding connector R1.C1/R1.C2 are located at the base.
Hose for compressed air is also integrated into the manipulator. There are 4 inlets
at the base (R1/8”)) and 4 outlets (M5) on the outer arm.
B
B
C
C
A
A
xx2000001161
Value
Number
Description
Connection
Position
Air hose with outer diamet-
er 4 mm, 2 pcs
4
Max. 6 bar
Air
A
Air hose with outer diamet-
er 6 mm, 2 pcs
30 V, 1.5 A
12 wires
Customer power/signal
C1
B
30 V, 1 A or 1 Gbits/s
8 wires
Customer power/signal
or ethernet
C2
C
Connector kits (optional)
Connector kits, base
R1.C1 and R1.C2 connectors on the base are parts of the CP/CS cable and Ethernet
floor cable, respectively. For details about the robot cabling, see "Robot cabling
and connection points" in robot product manual.
Continues on next page
Product specification - IRB 920
43
3HAC075723-001 Revision: A
© Copyright 2021 ABB. All rights reserved.