The procedure below details how to inspect the function of the UL-lamp.
Action
Note
1. Check that the UL-lamp is lit, when the motors are in
operation ("motors ON").
2. If the lamp is not lit, trace the fault!
•
Check whether the
UL-lamp
is broken. If so,
replace it.
•
Check the cable connections.
•
Measure the voltage in connectors motor axis 3
(=24V).
•
Check the cabling. Replace cabling if a fault is
detected.
Part no. is specified in
Required equipment on
page 189