5 Calibration information
5.5. Updating revolution counters
411
3HAC022033-001 Revision: K
©
Co
py
rig
h
t 200
4-
201
1 AB
B. All
ri
gh
ts reser
v
ed.
5. A dialog box is displayed warning that the updating operation cannot be undone:
•
Tap
Update
to proceed with updating the revolution counters.
•
Tap
Cancel
to cancel updating the revolution counters.
Tapping
Update
updates the ticked revolution counters and removes the tick from the
list of axes.
6.
CAUTION!
If a revolution counter is incorrectly updated, it will cause incorrect robot positioning,
which in turn may cause damage or injury!
Check the calibration position very carefully after each update.
See the section
Checking the calibration position on page 412
.