1 Description
1.3.2 Operating requirements
3HAC 025861-001
Rev.E
15
1.3.2 Operating requirements
Protection standards
Standard Manipulator IP54, Foundy Plus IP67.
Explosive environments
The robot must not be located or operated in an explosive environment.
Ambient temperature
Relative humidity
Description
Standard/Option
Temperature
Manipulator during
operation
Standard
+ 5°C (41°F) to + 50°C (122°F)
For the controller
Standard/Option
See Product specification -
Controller IRC5 with FlexPendant
For the spot welding
cabinet
Standard
+ 5°C (41°F) to + 45°C (113°F)
Complete robot during
transportation and
storage
Standard
- 25°C (- 13°F) to + 55°C (131°F)
For short periods (not
exceeding 24 hours)
Standard
up to + 70°C (158°F)
Description
Relative humidiy
Complete robot during transportation and storage
Max. 95% at constant temperature
Complete robot during operation
Max. 95% at constant temperature