![ABB HT846529 Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/abb/ht846529/ht846529_operation-manual_2837967033.webp)
Operation Manual / TPS50
4 Operation / 4.2 Servicing work
© Copyright 2021 . All rights reserved.
HZTL2401_EN
Rev.A
September 2021
NOTICE
Service inspection after 5 years
To prevent age- and stoppage-related machine damage, an inspection
by an ABB Turbocharging Service Station is recommended at the latest
5 years after the last service.
4.2.1
Service work every 25 … 50 hours
u
Visual inspection for air, exhaust gas, water and oil leaks.
u
Record operating data and enter it in the engine logbook.
u
Clarify the cause of any variances.
CAUTION
Unknown changes during operation
The consequences can range from an impairment to a breakdown.
u
Have unknown causes clarified by an ABB Turbocharging service sta-
tion.
4.2.2
Servicing work according to the engine
manufacturer's instructions
Oil filter
u
Clean or replace oil filter in supply line to turbocharger when engine is
not running.
Page
31
/
71