Oil pressure
The oil pressure in front of the turbocharger must be maintained pre-
cisely to ensure trouble-free operation.
Status for operation
Oil pressure in front
of turbocharger
[bar]
Normal operation
2.0 … 4.5
Engine start: cold oil, permissible for maximum 15
minutes
≤
8.0
Engine idling
≥
0.2
Pre- and post-lubrication (engine stopped)
≤
1.0
CAUTION
Prelubrication
Serious machine or property damage might result if the turbocharger is
not supplied with oil when the engine is starting.
u
Activate prelubrication device before starting engine.
3.2 Inspection work
Inspection work includes preventive visual controls plus monitoring and
measuring work before and during commissioning. Inspections help de-
tect changes to the turbocharger. Machine damage can be avoided.
3.2.1
Inspection before commissioning
Monitoring equipment
u
Check for correct functioning.
Oil filter
u
Check cleanliness before commissioning.
Manometers oil lines
u
Check the oil pressure in the oil supply lines.
CAUTION
It is strongly recommended that, before commissioning as well as fol-
lowing any servicing work on the lubricating system, you install a by-
pass pipe in order to thoroughly flush the entire lubricating system
with warm, clean oil.
Also, we strongly advise you to use a running-in filter when starting up
the engine for the first time as well as following all service work on the
lubricating system.