Operation Manual / TPL73-B.. - 85-B11/ -B12
5 Maintenance / 5.4 Cleaning the compressor during operation
© Copyright 2018 . All rights reserved.
HZTL2480_EN
Revision D
July 2018
5.4.2
Wet cleaning using vacuum cleaning device on filter
silencer (XC4)
In order to carry out a successful cleaning procedure that has been
tested and is recommended by ABB Turbo Systems, the following pre-
requisite must be met:
w
Engine load 25 ... 85%
w
If the engine compartment temperature is less than 0°C during wet
cleaning of the compressor, precautionary measures must be taken
to prevent ice formation.
u
Start cleaning cycle according to following description
Wet cleaning
operation with XC4.
Procedure for compressor wet cleaning with XC4
01Cleaning medium vessel
02Pipe
03Injection pipe
04Cleaning instructions
05Cover
06Valve
NOTICE
When using the cleaning medium vessel on the filter silencer, refer to
the detailed cleaning instructions on the sign (04) attached to the filter
silencer.