Fig. 12: Moving out cartridge group 1
1. Remove the O-ring (42012).
2. Loosen and remove the screws (42087).
3. Fit swivel lifting eye (90231) to bracket (90030) and screw bracket to cartridge group
with two screws (90955).
4. Fit five plates (90031) and secure with plate (90032), screw (90656) and nut (90432).
5. Secure lifting gear to swivel lifting eye (90231) and secure cartridge group to crane.
6. Evenly press off cartridge group by screwing three press-off screws (90920) into the des-
ignated holes.
Fig. 13: Moving out cartridge group 2
7. Carefully move out cartridge group.
8. Put cartridge group into the fixtures in the turned-over toolbox cover.
9. Remove plate (90032), screw (90656), nut (90432) and plates (90031).
10. Remove the press-off screws (90920).
11. Remove O-rings (42017 / 42018).