2.3 Software setup
2.3.1 Software setup overview
Setup of PROFINET devices
This information is valid if PROFINET is selected in the fieldbus selection in
Installation Manager.
From version 1.05 of the Fronius TPSi Add-in, the PROFINET setup is
pre-configured and ready to use. The only thing that the user needs to do, is to
change the IP of the welder if needed.
The IPPNIO.xml file is created during the installation the Robot system, and is
copied to the HOME folder of the system.
The latest version of the Fronius TPSi GSDML file is copied to the HOME/GSDML
folder on the system.
The default IP addresses for the welders are:
IP address
Welder
192.168.0.2
T_ROB1
192.168.0.3
T_ROB2
192.168.0.4
T_ROB3
192.168.0.5
T_ROB4
The IP address can be changed from the I/O Configurator:
xx2100000509
Application manual - Fronius TPS 320i/400i/500i/600i with RI-FB inside/i interface
17
3HAC065012-001 Revision: C