A.7 Installation guide
Working method
1 Ensure that the programming cable is connected between the computer and
Pluto #0.
2 Open the desired program in Pluto Manager.
3 Verify the checksum for the program according to the release notes.
4 Configure the appropriate Pluto program according to the cell specification
for the actual FlexLoader cell.
5 Load the program to Pluto.
6 Carry out the test for start up from non-powered status.
7 Check all safety functions.
CAUTION
In case of changes or deviations: Update cell specification.
A new validation is necessary if functional changes are made to the Pluto
program.
Configuring
1 Ensure that the programming cable is connected between the computer and
Pluto #0.
2 Open the desired program in Pluto Manager.
There are two basic versions of the Pluto program: One for an even number
of serially connected Eden DYN switches in the protective stop chain
(
PlutoStandardEven
), and another for an odd number of serially connected
Eden DYN switches in the protective stop chain (
PlutoStandardOdd
).
3 Select
Open with permission to configure
and enter the password
config123
.
Click
OK
.
xx1800000422
4 Verify the checksum for the program according to the release notes.
Continues on next page
62
Application manual - FlexLoader Standard Safety Center
3HAC051769-001 Revision: E
© Copyright 2014-2020 ABB. All rights reserved.
A Technical data
A.7 Installation guide
Содержание FlexLoader
Страница 1: ...ROBOTICS Application manual FlexLoader Standard Safety Center ...
Страница 6: ...This page is intentionally left blank ...
Страница 18: ...This page is intentionally left blank ...
Страница 28: ...This page is intentionally left blank ...
Страница 30: ...This page is intentionally left blank ...
Страница 42: ...This page is intentionally left blank ...
Страница 48: ...This page is intentionally left blank ...
Страница 52: ...This page is intentionally left blank ...
Страница 66: ......
Страница 67: ......