A.5 Pluto I/O
All inputs have filtering activated.
Comments
Designation
Out
In
Emergency stop In (FlexLoader buttons
and robot) (static)
InEmergencyStopInternalChA
I 0
Emergency stop In (FlexLoader buttons
and robot) (
DynA Non_inv
)
InEmergencyStopInternalChB
I 1
Protective stop In (from external machine,
option) (static, bridged to 24 V if not used)
InAutoStopExternalChA
I 2
Protective stop In (from external machine,
option) (
DynA Non_inv
, bridged to
DynA
if not used). Option: Can be configured
as sole dynamic input, set correct inver-
sion.
InAutoStopExternalChB
I 3
Emergency stop In (from external ma-
chine) (static, bridged to 24 V if not used)
InEmergencyStopExternalChA
I 4
Emergency stop In (from external ma-
chine) (
DynA Non_inv
, bridged to
DynA
if not used)
InEmergencyStopExternalChB
I 5
MotorsOn
signal from the FlexPendant
through the motor contactors (static,
bridged to 24 V if not used)
InMotorsOnChA
I 6
MotorsOn
signal from FlexPendant
through the motor contactors (
DynA
Non_inv
, bridged to
DynA
if not used)
InMotorsOnChB
I 7
Reset protective stop (static)
ResetAutoStop
IQ 10
Reset emergency stop (
DynA NonInv
,
option)
ResetEmergencyStop
ResetEmergencyStopLamp
IQ 11
IQ 11
Lamp in reset button (static, option)
Protective stop in door chain
•
Even numbers of doors:
DynA
Noninv
•
Odd numbers of doors:
DynA
AutoStopDoorChain
IQ 12
Supervision expansion, protective stop
(static)
SupervisionAutoStop
IQ 13
Supervision expansion, emergency stop
internal (static)
SupervisionEmergencyStopIn-
ternal
IQ 14
Push button inside the cell that must be
activated within the correct time window
before
ResetAutostop
is accepted.
ControlledExitButton
EnableLockDoor
IQ 15
IQ 15
Doubling signal that indicates that the
doors can be locked. Activated as soon
as neither protective stop nor emergency
stop are active.
Supervision expansion, external emer-
gency stop (static, option)
SupervisionEmergencyStopEx-
ternal
IQ 16
Generates signal
DynA
DynA
IQ 17
Emergency stop for external equipment
via expansion relay
OutEmergencyStopExternal
Q 0
Continues on next page
Application manual - FlexLoader Standard Safety Center
59
3HAC051769-001 Revision: E
© Copyright 2014-2020 ABB. All rights reserved.
A Technical data
A.5 Pluto I/O
Содержание FlexLoader
Страница 1: ...ROBOTICS Application manual FlexLoader Standard Safety Center ...
Страница 6: ...This page is intentionally left blank ...
Страница 18: ...This page is intentionally left blank ...
Страница 28: ...This page is intentionally left blank ...
Страница 30: ...This page is intentionally left blank ...
Страница 42: ...This page is intentionally left blank ...
Страница 48: ...This page is intentionally left blank ...
Страница 52: ...This page is intentionally left blank ...
Страница 66: ......
Страница 67: ......