2TLC172272M0201
Rev E
7
3
Models of Adam and Eva
Eden communicates with OSSD signals and can be connected to any safety module that handles
OSSD-signals. Up to 30 Eden sensors can be connected in series without reducing the achieved
performance level. Adam and Eva are acquired separately and it is possible to mix different models
of Adam OSSD in the same safety circuit.
Adam OSSD
Adam OSSD exists in four different models:
Adam OSSD-Info M12-8
OSSD model with information output, and inputs for
cascade connection.
Adam OSSD-Reset M12-8
OSSD model with built in monitored reset, indication lamp
output, and inputs for cascade connection.
Adam OSSD-Info M12-5
OSSD model with information output.
Adam OSSD-Reset M12-5
OSSD model with built in monitored reset and indication
lamp output.
Eva
Eva exists in two different models. The Eva units with general code have all the same code. The Eva
units with unique code have all a different unique code. The unique variant fulfils the requirements
for a high level coded interlocking device according to EN ISO 14119:2013. The Eva with general
code fulfils the requirement for a low level coded interlocking device. It is possible to mix different
models of Eva in the same safety circuit.
Eva General code
Eva with the same code.
Eva Unique code
Eva with a unique code.