![ABB EAS822 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/abb/eas822/eas822_instructions-manual_3540882006.webp)
6
5.1.2
EBS 862
On the electronics side, the power supply and the motor cable are connected via screw terminals, and
the signal cables are connected via an internal plug and socket connection.
The overall weight of the electronics EBS 862 is approx. 42 kg. For safety reasons it may be necessary
to install the two housing halves separately.
The electronics unit is provided with 5 PG cable glands:
IItem 1:
1 x PG 16 for mains connection
Item 2:
1 x PG 16 for motor connection cable
Item 3:
3 x PG 16 for signal cable
-
Undo and remove cover screws (4).
-
Fold down front part and disconnect internal plug connection between housing halves.
-
Undo hinge screw (5).
-
Lift off front part from hinge bolts towards top.
-
First, mount rear housing half.
-
Attach front housing half to hinge bolts, insert screw into top bolt and fasten.
-
Connect internal plug connection.
-
Close housing and fasten with cover screws (4).
Connect cable according to figure 10 (when applying the shield refer to figure 2 for details).
Fig. 2:
1 PG cable gland for mains connection
2 PG cable gland for
motor connection
3 PG cable glands for
signal connection
4 Cover screws
5 Hinge screws
6 Commissioning and service field (CSF)
1
2
3
4
4
5
6
d0112rxa