Field and Software Tools
CalMaster2 and CheckMaster
3 Installation
14
IM/VCM2
Issue 6
3.3.4 Fitting an AquaMaster Pulsed Output Socket
To fit an AquaMaster pulsed output socket:
1.
Turn off the power to the AquaMaster and remove the covers – see Section 3.3.2, page 12.
2.
Disconnect and withdraw the pulsed output cable
A
.
3.
Remove and discard the gland
B
.
4.
Feed the socket lead into the AquaMaster and fit the socket (MGFA0609-S)
C
.
5.
Connect the sensor cable
D
.
6.
Replace the covers – see Fig. 3.7, page 12.
Fig. 3.9 Fitting an AquaMaster Pulsed Output Socket
O/P3
O/P2
O/P1
O/P COM
+V
0V
DATA
Brown
Red
Orange
Yellow
Violet
Green
Blue
B
C
A
D