![ABB Busch E-contact Скачать руководство пользователя страница 74](http://html2.mh-extra.com/html/abb/busch-e-contact/busch-e-contact_system-manual_5043475074.webp)
Information about planning and application
System Manual 2CKA001473B9577
│
74
Examples of switching ABB flexTronics
®
L
N
16A
1
3
2
Fig. 25: Examples of switching: Single offices light control without extension unit input
[1] 64814 U-500 e-contact insert flex, 1-gang
[2] 64753-xxx Busch-Presence detector flex, universal sensor
[3] Lamp
Notice
When using the 64814 U-500 e-contact insert flex, 1-gang the connection of the
N-busbar is optional (broken line).
Limitations at reduced loads in 2-wire operation are possible.
L
N
16A
1
4
2
3
Fig. 26: Examples of switching: Single offices light control with extension unit input
[1] 64814 U-500 e-contact insert flex, 1-gang
[2] 64753-xxx Busch-Presence detector flex, universal sensor
[3] Extension unit push-button, e.g. 2020 US/500
[4] Lamp
Notice
When using the 64814 U-500 e-contact insert flex, 1-gang the connection of the
N-busbar is optional (broken line).
Limitations at reduced loads in 2-wire operation are possible.