![ABB ACSM1-204 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/abb/acsm1-204/acsm1-204_quick-installation-and-start-up-manual_3045238007.webp)
Quick installation and start-up guide – ACSM1-204 7
Cabling examples
U1
V1 W1
U2
V2 W2
R+
R-
UDC+UDC-
U2 V2 W2
U1 V1 W1
R- R+
Frame size A
Frame size B
Frame sizes C and D
Cable clamp on bare shield.
Bare shield. Cover with insulating tape.
Screw lug detail:
Connection to the drive modules.
Connection to the regen filter module.
Strain relief: draw conductors under clamp
or tighten conductors to clamp with cable
tie.
Connection to the brake chopper (optional).
1
2
3
4
5
6
2
1
4
5
6
1
4
5
6
2
3
1
5
6
4
2
UDC+ UDC-
UDC+
Lb/
UDC+
La/
La/
Lb/
2
2
2
ACSM1-204 Quick Quide.book Page 7 Tuesday, October 6, 2009 11:02 AM