Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
User Position CW1 bit
0 / int32
Selects a source that enables/disables the axis (and
start) commands when
is set to
. This command is always
level-triggered.
Enable sel
74.20
0
0.
False
1
1.
True
2
Digital input DI1 (
, bit 0).
DI1
3
Digital input DI2 (
, bit 1).
DI2
4
Digital input DI3 (
, bit 2).
DI3
5
Digital input DI4 (
, bit 3).
DI4
6
Digital input DI5 (
, bit 4).
DI5
7
Digital input DI6 (
, bit 5).
DI6
8
Digital input/output DIO1 (
, bit
0).
DIO1
9
Digital input/output DIO2 (
, bit
1).
DIO2
10
Bit 0 of
74.7 User Position control word 1
.
User Position CW1
bit 0
11
Bit 1 of
74.7 User Position control word 1
.
User Position CW1
bit 1
12
Bit 2 of
74.7 User Position control word 1
.
User Position CW1
bit 2
13
Bit 3 of
74.7 User Position control word 1
.
User Position CW1
bit 3
14
Bit 4 of
74.7 User Position control word 1
User Position CW1
bit 4
15
Bit 5 of
74.7 User Position control word 1
.
User Position CW1
bit 5
16
Bit 6 of
74.7 User Position control word 1
User Position CW1
bit 6
17
Bit 7 of
74.7 User Position control word 1
User Position CW1
bit 7
See
Terms and abbreviations (page 130)
.
Other [bit]
User Position CW1 bit
1 / int32
Selects the source of an external axis fault reset signal.
The signal resets an axis fault if the cause of the fault
no longer exists. This command is always
edge-triggered.
For the selections, see
Fault reset sel
74.21
False / int32
Selects the source of a jog signal (in the positive
direction).
This command is always level-triggered.
In case jogging is activated in both the positive and
negative directions, the one that was activated last
takes priority.
For the selections, see
Jog forward sel
74.22
Parameters 445
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...